Table 4 SAID values for PATH LINK (CL2) (continued)
Package
Port
SAID
Local
2RL
CL2-G
X'0016'
(Add3)
CL4-G
X'0036'
CL6-G
X'0056'
CL8-G
X'0076'
CL2-H
X'0017'
CL4-H
X'0037'
CL6-H
X'0057'
CL8-H
X'0077'

Command device

Business Continuity Manager requires a command device on the Continuous Access Synchronous
Z disk array that is independent of the command device for an open system. The command device
for BCM can be configured only from BCM.
To find the command device using Remote Web Console:
1.
In Remote Web Console, click File/Reports. The Report Display window displays.
2.
Click the LDEV tab.
If you are using XP12000 Disk Array/XP10000 Disk Array, only the volumes with a CU: LDEV
number between 00: 00 to 3F: FF can be used as command devices.

F/M = FB message output control option when operating R-VOLs

When the suspension or the release operation is performed from Business Continuity Manager
(BCM) to the R-VOL of Continuous Access Synchronous Z pair in the Duplex status, the status of
the M-VOL becomes Suspend and the F/M = FB message is output to the host connected to MCU.
You can control the output of this message by setting the system option mode 776.
However, even if the system option mode 776 is set, the F/M = FB message is output when the
pair status becomes Suspend due to the failure. Moreover, the F/M = FB message is not output
regardless of the setting of system option mode 776 if PPRC support by host = No is selected on
the CU Option dialog box.
Table 5 Whether to output the F/M = FB message when operating R-VOLs
Cause of the
suspension of M-VOL
Suspended by the
suspension or the
release operation from
BCM to R-VOLs
Suspended by failure
18
Requirements and specifications
Package
Port
SAID
Local
2UL
CL2-Q
X'001E'
(Add7)
CL4-Q
X'003E'
CL6-Q
X'005E'
CL8-Q
X'007E'
CL2-R
X'001F'
CL4-R
X'003F'
CL6-R
X'005F'
CL8-R
X'007F'
Settings
The system option mode 776 is ON
PPRC support by host
PPRC support by host
= Yes
= No
No
No
Yes
No
Package
Port
SAID
Local
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
The system option mode 776 is OFF
PPRC support by host
= Yes
Yes
Yes
Package
Port
SAID
Local
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PPRC support by host
= No
No
No