Fence level list (string): "N" or "Never" = never; "S" or "Status" = status; "D" or "Data" =
data; default = "Never". For async pairs you must either specify N (never) or omit this
parameter.
CFW flag list (numeric): 0 = copy CFW data to R-VOL; 1 = only M-VOL; default = 1.
DFW flag list (numeric): 0 = DFW not required; 1 = DFW required; default = 0. Must be
omitted for async pairs.
Error level list (string): To maintain interchangeability with the script made with the model
before XP12000 Disk Array/XP10000 Disk Array, this parameter has been left. Do not use
this parameter with P9500.
Time-Saving Mode flag: "Yes" = The Use Time-Saving Mode option is enabled; "No" = The
Use Time-Saving Mode option is disabled; default = "Yes". This parameter is a non-list type
and only one value can be specified.
Differential management measurement flag list (string): The differential between the volumes
is managed in cylinder ("Cylinder" or "C") or in track ("Track" or "T"). When "Auto" or "A"
is specified, the storage system selects the differential management measurement (cylinder or
track) automatically. The default is Auto.
Time stamp transfer list (string): "Enable" = The host I/O timestamp is transferred from M-VOL
to R-VOL; "Disable" = The host I/O timestamp is not transferred from M-VOL to R-VOL; default
= "Disable". For the async pairs you must omit this parameter.
The CreateHrcPair Command example that follows
example of the pair macro commands needed to create the specified pairs with the parameters
listed in the table.
CAUTION:
When using the CreateHrcPair command to create more than one pair, make
sure to keep each line within the maximum line length (320 bytes).
Table 52 CreateHrcPair parameters
Parameter
M-VOL
Serial number (RCU)
SSID (RCU)
R-VOL
Initial copy pace
Initial copy mode
Sync level
Priority
Fence level
CFW flag
DFW flag
Time-Saving Mode
Time stamp transfer
The full example of the pair macro commands needed to create the specified pairs with the
parameters listed in
Table 52 (page 111)
Table 52 (page 111)
Value
_ilDevA
_slWorkA
1 1
_ilDevB
_slWorkB
E
S0, S0, S0
_ilWorkA
Never
0
1
[omit – default]
Enable
is shown in two parts in the following two examples.
provides an
Operation macro commands
1 1 1