Hp_Deviceindication: Power Supply Redundancy Failed - HP BL685c - ProLiant - 4 GB RAM Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheets
Hide thumbs Also See for BL685c - ProLiant - 4 GB RAM:
Table of Contents

Advertisement

HP_DeviceIndication: Power Supply Redundancy
9-4-8
Lost
Table 9-25
HP_DeviceIndication: Power Supply Redundancy Lost
Property name
Description
AlertingManagedElement
AlertingElementFormat
AlertType
EventID
ProviderName
RecommendedActions
Summary
EventCategory
ProbableCause
ProbableCauseDescription

HP_DeviceIndication: Power Supply Redundancy Failed

9-4-9
This indication is not supported on ProLiant systems since redundancy set failure, which is failure
beyond redundancy lost, will cause system shutdown.
Table 9-26
HP_DeviceIndication: Power SupplyRedundancy Failed
Property name
PerceivedSeverity
Description
Property implementation
Power redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set that lost redundancy.
WBEM path of the SMX_WinPowerRedundancySet
instance representing the redundancy set where
redundancy was lost.
2 (CIMObjectPath)
5 (Device Alert)
6
HP Power
Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power
supplies if necessary.
HP_AlertIndication
Power redundancy has been lost.
16 (System Power)
88 (Loss of Redundancy)
Power Redundancy has been Lost
Property implementation
CIM_Indication
5 (Major)
CIM_AlertIndication
Power redundancy has been lost.
(RedundancySetCaption)where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set that failed redundancy.
System Power Supply 229