HP_DeviceIndication: Enclosure Temperature
4-4-24
sensor status changed to Critical
Table 4-109
HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
Property implementation
GUID string generated at indication
5 (major)
Time of indication
CIM_AlertIndication
A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs
WBEM Path of SMX_SAStorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
309
Time of the event or time of the indication if event time
unknown
HP SmartArray
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Temperature sensor Status changed to Critical.
24 (Primary Storage Cooling)
51 (Temperature Unnacceptable)
Temperature Status Changed to Critical
Contains a list of all the IP addresses of the computer
system generating the indication
SMX_OperatingSystem.OSType
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
Smart Array 142