Hp_Deviceindication: Controller Redundancy Has Been Lost - HP BL685c - ProLiant - 4 GB RAM Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheets
Hide thumbs Also See for BL685c - ProLiant - 4 GB RAM:
Table of Contents

Advertisement

HP_DeviceIndication: Controller Redundancy state
4-4-10
has been set to Active
Table 4-95
HP_DeviceIndication: Controller Redundancy state has been set to Active
Property name
VariableTypes[]
VariableValues[]
DeviceModel
HP_DeviceIndication: Controller Redundancy has
4-4-11
been lost
Table 4-96

HP_DeviceIndication: Controller Redundancy has been lost

Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
Property implementation
String (1)
uint32 (5)
FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
Array Controller Model string
Property implementation
CIM_Indication
GUID string generated at the time of indication
3 (Warning)
Time of indication
CIM_AlertIndication
A Smart Array controller has detected that redundancy
has been lost due to failure or loss of communication
with partner controller.
WBEM Path to SMX_SAArrayController class.
2 (CIMObjectPath)
5 (Device Alert)
4
Time of the event or time of the indication if event time
unknown
HP Smart Array
Check status of the partner array controller.
Name of the computer system generating the indication
Smart Array 111