HP BL685c - ProLiant - 4 GB RAM Datasheet page 132

Hp insight management wbem providers for hp integrated vmware esxi data sheets
Hide thumbs Also See for BL685c - ProLiant - 4 GB RAM:
Table of Contents

Advertisement

HP_DeviceIndication: Enclosure Power Supply
4-4-19
status changed to Non Redundant
Table 4-104
HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
Property implementation
HP_AlertIndication
Power Supply Status changed to Non-Redundant.
17 (Primary Storage Power)
89 (Power Supply Failure)
Redundant Power Supply Status Changed to Non-
Redundant
Contains a list of all the IP addresses of the computer
system generating the indication
SMX_OperatingSystem.OSType
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
2.2.0.0
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Smart Array 132