Table 9-18
Provider Indication Common Properties
Property name
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
HP_DeviceIdentification: Power Supply Removed
9-4-2
The following indications are implemented for ProLiant server platforms where available. System
Power Supply indications are described below.
Table 9-19
HP_DeviceIdentification: Power Supply Removed
Property name
PerceivedSeverity
Description
AlertingManagedElement
AlertingElementFormat
AlertType
EventID
ProviderName
RecommendedActions
Summary
EventCategory
ProbableCause
ProbableCauseDescription
Property implementation
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
Property implementation
CIM_Indication
2 (Information)
CIM_AlertIndication
A power supply has been removed. (Power Supply),
where Power Supply is the system power supply that
was removed
WBEM path of the SMX_WinPowerSupply instance
2 (CIMObjectPath)
5 (Device Alert)
1
HP Power
Check the system power supply configuration. Verify
that this power supply was removed intentionally.
HP_AlertIndication
Power Supply removed
16 (System Power)
1 (Other)
Power Supply Removed
System Power Supply 224