Cabletron Systems SSIM-A2-01 Installation And User Manual page 32

Atm 155 smartstack interface modules
Table of Contents

Advertisement

23
Maximum Number Elements in STAT PDU
Sets the maximum number of list elements placed in a STAT PDU.
Possible values: 3 to 1023.
Default: 67.
Maximum SDU Size (bytes)
Sets the maximum size of the service data unit (SDU) in bytes.
Possible values: 512 to 16,384.
Default: 4096.
Maximum UU Size (bytes)
Sets the maximum size of the user-to-user (UU) unit in bytes.
Possible values: 512 to 16,384.
Default: 4096.
Poll Timer (msec)
Sets the frequency at which the peer receiver is polled for status in milliseconds.
Possible values: 1 to 10,000.
Default: 300.
STAT PDU Timeout (sec)
Sets the maximum time interval during which at least one STAT PDU must be
received. The value must be at least SscopTimer_NO_RESPONSE + round-trip
delay.
Possible values: 1 to 255.
Default: 7.
Keep Alive Timer (sec)
Sets the value of the Keep Alive Timer variable. As a guideline, set the value
greater than Timer_POLL and round-trip delay.
Possible values: 1 to 255.
Default: 1.
Idle Timer (sec)
Defines the idle period during which no POLL PDUs are sent, and when there are
no unacknowledged SD PDU transmits. The value set may be much greater than
Timer_KEEP_ALIVE.
Possible values: 1 to 255.
Default: 2.
SmartStack SSIM-A2-01/SSIM-A8-01
Console Configuration