Figure 3-3 Installing a Side Clip GPIM into the Module
3.2.1.2
Removing the Side Clip GPIM
CAUTION: Do NOT remove a GPIM from a slot without unlocking the tabs. This can
damage the GPIM.
The GPIM and the module are sensitive to static discharges. Use an antistatic wrist
strap and observe all static precautions during this procedure. Failure to do so could
result in damage to the GPIM or module. Always leave the GPIM in the antistatic bag or
an equivalent antistatic container when not installed.
Remove a GPIM from its slot in a module as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap package)
before removing the GPIM.
2. Remove any cables connected to the GPIM.
3. Locate the locking tabs that are on the side of the GPIM. See
4. Squeeze both locking tabs in towards the center of the GPIM. This will unlock the GPIM clips.
5. Grasp the sides of the GPIM while squeezing the tabs and pull it out of the port.
6. If storing or shipping the GPIM, insert the dust protector into the GPIM to protect the fiber ports.
Installing Options into the 5G106-06
Figure
3-3.
Installation
3-5
Need help?
Do you have a question about the Matrix E6 5G102-06-G and is the answer not in the manual?
Questions and answers