Enterasys Matrix E6 5G102-06-G Install Manual page 59

Gigabit ethernet modules
Hide thumbs Also See for Matrix E6 5G102-06-G:
Table of Contents

Advertisement

• Switch 7 – Clear NVRAM. Changing the position of this switch resets NVRAM on the next
power-up of the device. All user-entered parameters, such as the IP address, device names, etc.,
are reset to the factory default settings. Once the module resets, you can either use the factory
default settings or reenter your own parameters.
• Switch 8 – Reset Password/Community Names. Changing the position of this switch clears
user-entered passwords stored in NVRAM, and restores the factory default passwords on the
next power-up of the device. Once the module resets, you can either use the factory default
settings or reenter your own passwords.
NOTE: Do not change the position of Switch 8 unless it is necessary to reset the
super-user configured passwords to their factory default settings.
Setting the Mode Switches
Mode Switch Bank Settings
B-3