And Y Parallel Movement Of Sewing Pattern - Brother BAS-342G Instruction Manual

Direct drive, programmable electronic pattern sewer
Hide thumbs Also See for BAS-342G:
Table of Contents

Advertisement

7. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
7-10. X and Y parallel movement of sewing pattern
You can move the feed mechanism to the desired position to move an already-programmed sewing pattern in a parallel
direction up, down or to the left or right.
1
2
Depress the work clamp switch (1) to lower the work clamp.
3
TEST indicator illuminates, X-SCALE indicator flashes
4
X-scale
parallel movement mode
5
End parallel movement mode
NOTE:
• The feed mechanism will not move to a position that would move the sewing pattern outside the sewing area.
• If you change the program number, X-scale or Y-scale settings, the amount of movement recorded will be reset.
• In addition, the amount of movement will be reset if the power switch is turned off and then back on again. However,
memory switch No. 465 is set to "ON", the amount of movement will be recorded and will not be reset. (Refer to the
service manual for details on memory switch No. 465.)
45
Y-scale
parallel movement mode
4560Q
4561Q
TEST indicator switches off
BAS-342G
1. Press the
or
key to select the program number.
2. Depress the work clamp switch (1) to lower the work
clamp, and then depress the start switch (2).
• The work clamp will move to the sewing start
position.
While pressing the TEST key, press the
• The parallel movement amount will appear in the menu
display in units of mm.
Press the SELECT key to switch between the X-SCALE
indicator and Y-SCALE indicator flashing. Select either
direction.
The work clamp will move by 0.05 mm each time the
or
key is pressed. (When the distance reaches 10
mm, the amount of movement will change to 0.1 mm.)
• When using X-scale parallel movement mode, the
needle moves the corresponding distance to the right
when the
key is pressed, and to the left when the
key is pressed.
• When using Y-scale parallel movement mode, the
needle moves the corresponding distance backward
when the
key is pressed, and forward when the
key is pressed.
Press the TEST key.
4974Q 4014M
key.
4975Q 4559Q

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents