Table Of Error Codes - Brother BAS-342G Instruction Manual

Direct drive, programmable electronic pattern sewer
Hide thumbs Also See for BAS-342G:
Table of Contents

Advertisement

12. TABLE OF ERROR CODES

Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the cover of the control box. Touching areas where high voltages are present can result in severe
injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
E010
Stop switch was pressed. Press the RESET key to clear the error.
Stop switch was pressed. Press the RESET key to clear the error.
E011
Press the
The stop switch was still being pressed, or there is a problem with the stop switch connection.
E015
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
Problem with the stop switch connection.
E016
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
The power was turned on while the start switch was still being depressed, or the start switch was depressed
without the work clamp being lowered.
If the power has been turned on while the start switch was still depressed, turn off the power and check the start
E025
switch.
If the start switch was depressed without lowering the work clamp, depress the work clamp switch to lower the
work clamp.
The work clamp switch is depressed.
E035
Turn off the power, and then check the work clamp switch.
A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly.
E036
Use a foot switch that matches specifications, or initialize the memory switch settings.
Machine head tilting was detected after the power was turned on.
E050
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
Machine head tilting was detected while the sewing machine was operating.
E051
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.
Machine head tilting was detected when the power was turned on.
E055
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
An operation panel key was still being pressed when the power was turned on, or key is faulty.
E065
Turn off the power and check the operation panel.
Upper shaft motor-related errors
Code
Needle up stop position error.
E110
Turn the machine pulley until the point where the error display disappears.
Upper shaft did not stop at the needle up stop position when the sewing machine stopped.
E111
Turn the machine pulley until the point where the error display disappears.
Needle drop signal could not be detected.
E120
Turn off the power, and then check the synchronizer connection.
Thread trimming was not completed.
E121
Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn.
key to move the work clamp so that you can continue sewing.
DANGER
Cause and remedy
Cause and remedy
BAS-342G
12. TABLE OF ERROR CODES
(Continued on next page)
66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents