10-3. Checking the regulator

10-4. Cleaning the control box air inlet ports

4027M

10-5. Cleaning the eye guard

10-6. Checking the needle

10-7. Lubrication

Lubricate the sewing machine while referring to "4-18. Lubrication".
1. If water collects in the bottle of the regulator (1), turn the
drain cock (2) in the direction of the arrow to drain the
water.
2. After draining the water, tighten the drain cock (2).
4026M
Use a vacuum cleaner to clean the filter in the air inlet ports
(2) of the control box (1) at least once a month.
Wipe the eye guard clean with a soft cloth.
NOTE:
Do not use solvents such as kerosene or thinner to clean
the eye guard.
4987Q
Always check that the tip of the needle is not broken and
also that the needle is not bent before starting sewing.