4. INSTALLATION

4-11. Adjusting the air pressure [6]

4-12. Adjusting the speed controller [7]

Upper knob
Lower knob
Valve 2
11
3975M
Valve 1
3976M
BAS-342G
Lift up the handle (2) of the regulator (1) and then turn it to
adjust the air pressure to 0.5 MPa.
After adjustment is complete, push the handle (2) downward to
lock it.
You can adjust the lifting and lowering speeds for the work
clamp using the knobs on the valves.
• When the upper knob is tightened, the lifting speed becomes
slower. When it is loosened, the lifting speed becomes faster.
• When the lower knob is tightened, the lowering speed
becomes slower. When it is loosened, the lowering speed
becomes faster.
Reference adjustments
Upper knob
Valve 1
Lower knob
Upper knob
Valve 2
Lower knob
You can operate the work clamp when the power is turned off
by pressing the manual buttons (1).
Fully tighten
Fully tighten and then loosen by
8 turns
Fully tighten and then loosen by
5 turns
Fully tighten