Symptoms and Solutions
Table 6-9
Error Code Definitions (continued)
Error Code
Problem
166-415-001
System Management: Failed.
I2C bus failure.
180-XXX-000
Diagnostics LED failure.
180-XXX-001
Failed front LED panel test.
180-XXX-002
Failed diagnostic LED panel
test.
180-361-003
Failed fan LED test.
180-XXX-003
Failed system board LED test.
180-XXX-005
Failed hard disk drive backplane
LED test.
201-XXX-0nn
Failed memory test.
nn = slot number of failing
DIMM.
201-XXX-n99
Multiple DIMM failure; see
error text.
n = the number of the failing pair
of DIMMs.
Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide
6-38
Chapter 6
Troubleshooting the System Hardware
Action
Disconnect all power cords and external
1.
cables from the device, wait 30 seconds,
reconnect, and retry.
Reflash or update firmware to the latest
2.
level.
Reseat the operator information panel
3.
cable.
Check the system board.
4.
Run diagnostic panel LED test for the failing
LED.
1.
Reseat the operator information panel
cable.
2.
Check the system board.
Reseat the operator information panel
1.
cable.
Check the system board.
2.
Reseat the fan(s).
1.
2.
Check the system board.
Check the system board.
Reseat the hard disk drive backplane cable
1.
and backplane.
Check the system board.
2.
Replace the DIMM in the slot identified by
1.
nn.
Check the system board.
2.
See the error text to identify the failing
1.
DIMM pair and replace it.
Check the system board.
2.