HP AA979A - StorageWorks SAN Switch 2/8V Administrator's Manual page 430

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, november 2009)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

Table 98
Zone merging scenarios (continued)
Description
cfg content mismatch
Same content - different effective
cfg name
Same content - different zone name defined: cfg1
Same content - different alias name
Same name - different types
Same name - different types
Same name - different types
414 Zone merging scenarios
Switch A
defined: cfg1
zone1: ali1; ali2
effective: irrelevant
defined: cfg1
zone1: ali1; ali2
effective: irrelevant
defined: cfg1
zone1: ali1; ali2
effective: cfg1
zone1: ali1; ali2
zone1: ali1; ali2
effective: irrelevant
defined: cfg1 ali1: A; B
effective: irrelevant
effective: zone1:
MARKETING
effective: zone1:
MARKETING
effective:cfg1:
MARKETING
Switch B
defined: cfg1
zone1: ali3; ali4
effective: irrelevant
defined: cfg1
zone1: ali1; ali4
effective: irrelevant
defined:cfg2
zone1: ali1; ali2
effective:cfg2
zone1: ali1; ali2
defined: cfg1
zone2: ali1; ali2
effective: irrelevant
defined:cfg1:ali2: A; B
effective: irrelevant
effective: cfg1:
MARKETING
effective: alias1:
MARKETING
effective:alias1:
MARKETING
Expected results
Fabric segments due to: Zone
Conflict content mismatch
Fabric segments due to: Zone
Conflict content mismatch
Fabric segments due to: Zone
Conflict cfg mismatch
Fabric segments due to: Zone
Conflict content mismatch
Fabric segments due to: Zone
Conflict content mismatch
Fabric segments due to: Zone
Conflict type mismatch
Fabric segments due to: Zone
Conflict type mismatch
Fabric segments due to: Zone
Conflict type mismatch