Non-Matching Fabric-Wide Consistency Policies - HP AA979A - StorageWorks SAN Switch 2/8V Administrator's Manual

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, november 2009)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

Non-matching fabric-wide consistency policies

You may encounter one of the following two scenarios:
Merging a fabric with a strict policy to a fabric with an absent, tolerant, or non-matching strict policy.
The merge fails and the ports are disabled.
Table 32
shows merges that are not supported:
Table 32
Examples of strict fabric merges
Fabric-wide consistency policy setting
Strict/Tolerant
Strict/Absent
Strict/Strict
Merging fabrics with tolerant and absent policies. See
Table 33
Fabric merges with tolerant/absent combinations
Fabric-wide consistency policysetting
Tolerant/Absent
116 Configuring advanced security
Fabric A
Fabric B
SCC:S;DCC:S
SCC;DCC:S
SCC;DCC:S
SCC:S;DCC
SCC:S;DCC:S
SCC:S
DCC:S
SCC:S
DCC:S
Fabric A
Fabric B
SCC;DCC
DCC
SCC;DCC
SCC
DCC
SCC
Expected behavior
Ports connecting switches are disabled.
Table 33
for examples:
Expected behavior
Error message logged.
Run fddCfg --fabwideset
"<policy_ID>" from any switch
with the desired configuration to fix
the conflict. The
secPolicyActivate command
is blocked until conflict is resolved.

Advertisement

Table of Contents
loading

Table of Contents