Troubleshooting

The following sources provide useful problem-solving information:
The standard support commands (portLogDump, supportSave, supportShow) or the Fabric
Manager Event Log
By default, the FICON group in the supportShow output is disabled. To enable the capture of FICON
data in the supportShow output, enter the supportshowcfgenable ficon command. After you
get confirmation that the configuration has been updated, the following will be collected and appear in
the output for the supportShow command:
• ficoncupshow fmsmode
• ficoncupshow modereg
• ficondbg dump rnid
• ficondbg log
• ficonshow ilir
• ficonshow lirr
• ficonshow rlir
• ficonshow rnid
• ficonshow switchrnid
• ficucmd dump -A
Other detailed information for protocol-specific problems:
• Display port data structures using the ptDataShow command.
• Display port registers using the ptRegShow command.

Identifying ports

The ficonshow rlir command displays, among other information, a tag field for the switch port. You
can use this tag to identify the port on which a FICON link incident occurred. The tag field is a
concatenation of the switch domain ID and port number, in hexadecimal format. The following example
shows a link incident for the switch port at domain ID 120, port 93 (785d in hex):
switch:admin> ficonshow rlir
{
{Fmt
Type PID
0x18 F
Port Status:
Link Failure Type:
Registered Port WWN
50:05:07:64:01:40:16:03 50:05:07:64:00:c1:69:ca
Type number:
Model number:
Manufacturer:
Plant of Manufacture: 02
Sequence Number:
tag:
Switch Port WWN
20:5d:00:60:69:80:45:7c 10:00:00:60:69:80:45:7c
Type number:
Model number:
Manufacturer:
Plant of Manufacture: CA
Sequence Number:
tag:
}
}
The Local RLIR database has 1 entry.
switch:admin> ficonshow rlir
254 Administering FICON fabrics
Port
Incident Count
785d00
93
Link not operational
Loss of signal or synchronization
Registered Node WWN
002064
103
IBM
0000000169CA
155d
Switch Node WWN
SLKWRM
24K
BRD
000000000078
785d
TS Format
Time Stamp
1
Time server Thu Apr 22 09:13:32 2004
Flag
Node Parameters
0x10
0x200115
Flag
Node Parameters
0x00
0x200a5d