Converting Port Number To Area Id - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 5.3.x administrator guide (5697-0244, november 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Converting port number to area ID

Except for the following cases, the area ID is equal to the port number:
when you perform a port swap operation
when you enable Extended Edge (also known as "displaced PID") PID on the Director
If you are using Extended Edge PID format (for example, the 4/256 SAN Director with configuration option
5) and would like to map the output of the port number to the area ID, use the following formula (for ports
0- 1 27):
a = (p + 16) % 128
where:
aarea
pport number
%modulus (or remainder)
0 p 128
Fabric OS 5.3.0 administrator guide 433