HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual page 299

Hp storageworks fabric os 5.3.x administrator guide (5697-0244, november 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

To check the Name Server (NS)
1.
Enter the nsShow command on the switch to which the device is attached:
The Local Name Server has 9 entries {
Type Pid
COS
*N
021a00;
2,3;20:00:00:e0:69:f0:07:c6;10:00:00:e0:69:f0:07:c6; 895
Fabric Port Name: 20:0a:00:60:69:10:8d:fd
NL
051edc;
3;21:00:00:20:37:d9:77:96;20:00:00:20:37:d9:77:96; na
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee0;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee1;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee2;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee4;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee8;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051eef;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
N
051f00;
2,3;50:06:04:82:bc:01:9a:0c;50:06:04:82:bc:01:9a:0c; na
FC4s: FCP [EMC
Fabric Port Name: 20:0f:00:60:69:10:9b:5b
2.
Look for the device in the NS list, which lists the nodes connected to that switch, allowing you to
determine if a particular node is accessible on the network.
• If the device is not present in the NS, the problem is between the storage device and the switch.
There might be a time-out communication problem between edge devices and the Name Server, or
there might be a login issue. First check the edge device documentation to determine if there is a
time-out setting or parameter that can be reconfigured. You should also check the port log for NS
registration information and FCP probing failures (using the fcpProbeShow command). If these
queries do not help solve the problem, contact the support organization for the product that appears
to be inaccessible.
• If the device is listed in the NS, the problem is between the storage device and the host. There might
be a zoning mismatch or a host/storage issue. Proceed to
page 312.
3.
Enter the portLoginShow command to check the port login status.
4.
Enter the fcpProbeShow command to display the FCP probing information for the devices attached to
the specified F_Port or L_Port. This information includes the number of successful logins and SCSI
INQUIRY commands sent over this port and a list of the attached devices.
5.
Check the port log to determine whether or not the device sent the FLOGI frame to the switch, and the
switch probed the device.
PortName
3;21:00:00:20:37:d9:73:0f;20:00:00:20:37:d9:73:0f; na
3;21:00:00:20:37:d9:76:b3;20:00:00:20:37:d9:76:b3; na
3;21:00:00:20:37:d9:77:5a;20:00:00:20:37:d9:77:5a; na
3;21:00:00:20:37:d9:74:d7;20:00:00:20:37:d9:74:d7; na
3;21:00:00:20:37:d9:6f:eb;20:00:00:20:37:d9:6f:eb; na
3;21:00:00:20:37:d9:77:45;20:00:00:20:37:d9:77:45; na
SYMMETRIX
NodeName
TTL(sec)
0005]
0005]
0005]
0005]
0005]
0005]
0005]
5267]
"To check for zoning
Fabric OS 5.3.0 administrator guide 311
problems" on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents