Using legacy commands for SNMPv1

You should use the snmpConfig command to configure the SNMPv1 agent and traps (refer to
snmpConfig
command" on page 101). However, if necessary for backward compatibility, you can choose
to use legacy commands.
Sample SNMP agent configuration information
switch:admin> agtcfgshow
Current SNMP Agent Configuration
Customizable MIB-II system variables:
SNMPv1 community and trap recipient configuration:
Community 1: Secret C0de (rw)
Trap recipient: 192.168.1.51
Trap recipient Severity level: 4
Community 2: OrigEquipMfr (rw)
Trap recipient: 192.168.1.26
Trap recipient Severity level: 0
Community 3: private (rw)
No trap recipient configured yet
Community 4: public (ro)
No trap recipient configured yet
Community 5: common (ro)
No trap recipient configured yet
Community 6: FibreChannel (ro)
No trap recipient configured yet
SNMP access list configuration:
Entry 0:
Entry 1:
Entry 2:
Entry 3:
Entry 4:
Entry 5:
104 Configuring standard security features
sysDescr = FC Switch
sysLocation = End User Premise
sysContact = Field Support.
authTraps = 1 (ON)
Access host subnet area 192.168.64.0 (rw)]
No access host configured yet
No access host configured yet
No access host configured yet
No access host configured yet
No access host configured yet
"Using the