Sample Rmf Configuration File For Mainframe - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 5.3.x administrator guide (5697-0244, november 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

In the following sample IOCP configuration file, the UNIT value for FICON CUP definitions is 2032 for
any FICON Director regardless of vendor or platform. So all SAN Switch 2/32, SAN Switch 4/32, SAN
Switch 4/32B, or SAN Director 2/128 switches require UNIT=2032 for the CUP definition. All Domain
IDs are specified in hex values in the IOCP (and not in decimal values); the Domain IDs in the example are
for demonstration purposes only.
*------------------------------------------------------------------
* SAN Director 2/128 Domain_ID=61 (in hex)
*------------------------------------------------------------------
CNTLUNIT CUNUMBR=0D8,UNITADD=00,UNIT=2032,
PATH=(50,51),
LINK=(61FE,61FE)
IODEVICE ADDRESS=(0D8,1),CUNUMBR=0D8,UNIT=2032,STADET=Y,UNITADD=00
*---------------------------------------------------------------
CNTLUNIT CUNUMBR=0D9,UNITADD=00,UNIT=2032,
PATH=(8A,8B),
LINK=(22FE,22FE)
IODEVICE ADDRESS=(0D9,1),CUNUMBR=0D9,UNIT=2032,STADET=Y,UNITADD=00
*------------------------------------------------------------------
* SAN Switch 2/32 Domain_ID=25 (in hex)
*------------------------------------------------------------------
*
CNTLUNIT CUNUMBR=0DB,UNITADD=00,UNIT=2032,
PATH=(5A,5B),
LINK=(25FE,25FE)
IODEVICE ADDRESS=(0DB,1),CUNUMBR=0DB,UNIT=2032,STADET=Y,UNITADD=00
*
*------------------------------------------------------------------

Sample RMF configuration file for mainframe

Resource Management Facility (RMF) is a performance management tool that measures selected areas of
system activity, including different views of the FICON channel. RMF presents data collected in the form of
System Management Facility (SMF) records. This data is essential for any kind of FICON channel
performance troubleshooting.
To obtain an RMF FICON Director activity report, you must include the keyword "FCD" in the RMF
configuration file for the FICON Director (this is generic for any FICON Director). You must also define the
CUP port. In the sample below, the keyword is boldfaced.
284 Administering FICON fabrics

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents