This command will cause the active CP to reset and will require
that existing telnet or SSH sessions be restarted.
Do you want to continue [Y]: y
The firmware is being downloaded to the Standby CP. It may take up to 10 minutes
Do you want to continue [Y]: y
12.
Optionally, after the failover, connect to the switch, and log in again as admin. Using a separate
session to connect to the switch, enter the firmwareDownloadStatus command to monitor the
firmware download status.
sw77:root> firmwareDownloadstatus
[1]: Thu Jul 28 00:30:49 2005
Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes.
[2]: Thu Jul 28 00:30:49 2005
Slot 7 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes.
[3]: Thu Jul 28 00:37:42 2005
Slot 2 (SAS): Firmware has been downloaded successfully to the blade.
[4]: Thu Jul 28 00:37:42 2005
Slot 7 (SAS): Firmware has been downloaded successfully to the blade.
[5]: Thu Jul 28 00:37:50 2005
Slot 2 (SAS): Blade is rebooting.
[6]: Thu Jul 28 00:37:50 2005
Slot 7 (SAS): Blade is rebooting.
[7]: Thu Jul 28 00:37:50 2005
Slot 2 (SAS): Firmware commit is started.
[8]: Thu Jul 28 00:37:50 2005
Slot 7 (SAS): Firmware commit is started.
[9]: Thu Jul 28 00:37:50 2005
Slot 2 (SAS): Firmware commit has completed.
[10]: Thu Jul 28 00:37:50 2005
Slot 7 (SAS): Firmware commit has completed.
(Firmwaredownload has completed.)
Fabric OS 5.3.0 administrator guide 183