3.2.3.8 Fan Motor (M3) Removal
top
from the light or place it in a dark area.
2. Remove the control panel. (Refer to Section 3.2.L3.)
3. Remove the paper cover.
4. Remove the right cover and left cover. (Refer to Section 3.2.2.)
5. Remove the top cover.
6. Remove the rear frame. (Refer to Section 3.2.2.2.)
7. Remove 2 CCB screws (M3x 8), and remove the fan motor (M3).
3.2.3.9 Fusing Unit Removal
1.
top cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it
Open
the
from the light or place it in a dark area.
Remove the control panel. (Refer to Section 3.2.l-3.)
2.
Remove the paper cover.
3.
Remove the right cover and left cover. (Refer 10 Section 3.2.2.)
Remove the upper unit.
5.
6.
Remove the rear frame. (Refer to Section 3.2.2.2.)
7.
sensor, and CN4 on the power supply board (PWB-E).
Remove 2 CP(0) screws (M3
8.
Figure 3-18. Removing the Fusing Unit
Rev. A
Remove the imaging cartridge. Cover the imaging cartridge to protect it
8)
X
Figure 3-17. Removing the Fan
6) on the fusing unit, and remove the fusing unit.
x
Motor
X 6)
3-15