Fusing Unit Removal And Disassembly; Fusing Unit Removal; Pressure Roller Removal - Epson C11C605001 - DFX 9000 B/W Dot-matrix Printer Service Manual

Terminal printer
Hide thumbs Also See for C11C605001 - DFX 9000 B/W Dot-matrix Printer:
Table of Contents

Advertisement

Service Manual

Fusing Unit Removal and Disassembly

3.2.5
This section describes how to remove and disassemble the fusing unit.

3.2.5.1 Fusing Unit Removal

1.
Remove the top cover. (Refer to Section 3.2.1.2.)
2. Disconnect comector P/Jl19 from the eject sensor.
3 Remove 1 CB screw (M3 x 6) securing the fusing unit.
4. Loosen 2 screws securing the fusing unit, and remove it.

3.2.5.2 Pressure Roller Removal

1.
Remove the top cover. (Refer to Section 3.2.1.2.)
2. Remove the fusing unit. (Refer to Section 3.2.5.l.)
3 Remove 2 CBB screws (M3 x 8) securing the fusing unit top cover,
4. Remove 2 CBB screws (M3 x 8) securing the fusing unit cover R, and remove it.
5. Remove 2 CBB screws (M3 x 8) securing the fusing unit cover L, and remove it.
6. Remove 1 CB screw (M3 x 6) on the fusing unit frame.
7. Remove the pressure roller.
Figure 3-38. Removing the Pressure
Rev. A
Figure 3-37. Removing the Fusing Unit
Disassembly and Assembly
remove it.
and
Roller
3-23