Heat Roller Removal

3.2.5.6
1.
Remove the top cover. (Refer to Section 3.2.1.2.)
Remove the fusing unit. (Refer to Section 3.2.5.1.)
2.
Remove 2 CB screws (M3 x 6) securing the inlet chute at the bottom of the fusing unit, and
3
remove the inlet chute.
4.
Remove 2 CBB screws (M3 x 8) securing the fusing unit top cover, and remove it.
5.
Remove 2 CBB screws (M3
6.
Remove 2 CBB screws (M3
Remove the pressure roller. (Refer to Section 3.2.5.2.)
7.
Remove the eject chute. (Refer to Se&On 3.25.3.)
8.
Remove the heater. (Refer to Section 3.2.5.5.)
9.
Remove the H/R ring securing the right side of the heat roller, and remove the H/R gear.
10.
11.
Remove the heat roller along with the left H/R ring and H/R bearing L.
12.
Remove the H/R ring and H/R bearing L from the heat roller.
o
H/R
Bearing

Figure 3-42. Removing the Heat Roller

3-26
8) securing the fusing unit cover R, and remove it.
x
8) securing the fusing unit cover L, and remove it.
x
ear
H/R
Ring