4 Slightly lift up the front of the system board and maneuver the system
board to the bottom of the chassis until it lays completely flat.
5 Push the system board toward the back of the chassis until the board is in
place.
6 Tighten the ten screws that secure the system board to the chassis. See
Figure 3-21.
7 Transfer the processor and the heat sink to the new system board. See
"Removing a Processor" on page 82 and "Installing a Processor" on page 86.
8 Replace all the memory modules and memory blanks. See "Installing
Memory Modules" on page 71.
9 Connect the cables in the order listed below (see
locations of the connectors on the system board):
SATA interface cable, if applicable
Control panel interface cable
Optical drive power cable
Control panel USB interface cable
System board power cables
10 Install the expansion card, if any. See "Installing an Expansion Card" on
page 62.
11 If applicable, reinstall the iDRAC6 Enterprise card. See "Installing an
iDRAC6 Enterprise Card" on page 79.
12 If applicable, reinstall the iDRAC6 Express card. See "Installing an
iDRAC6 Express Card" on page 76.
13 Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 69.
14 Close the system. See "Closing the System" on page 51.
15 Reconnect the system to its electrical outlet and turn the system on,
including any attached peripherals.