System Messages

System messages appear on the screen to notify you of a possible problem
with the system.
NOTE:
If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
Message
BIOS
MANUFACTURING
MODE detected.
MANUFACTURING
MODE will be
cleared before
the next boot.
System reboot
required for
normal
operation.
Caution!
NVRAM_CLR jumper
is installed on
system board.
Please run
SETUP.
Invalid
configuration
information -
please run SETUP
program.
Keyboard
controller
failure.
Causes
System is in manufacturing
mode.
NVRAM_CLR jumper is
installed in the clear setting.
CMOS has been cleared.
An invalid system
configuration caused a
system halt.
Faulty keyboard controller;
faulty system board.
Corrective Actions
Reboot to take the system
out of manufacturing mode.
Move the NVRAM_CLR
jumper to the default
position (pins 3 and 5). See
Figure 6-1 for jumper
location. Restart the system
and re-enter the BIOS
settings. See "Using the
System Setup Program and
Boot Manager" on page 25.
Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and Boot Manager" on
page 25.
See "Getting Help" on
page 119.