Troubleshooting The System Battery - Dell External OEMR R210II Owner's Manual

Ultra-compact rack server
Hide thumbs Also See for External OEMR R210II:
Table of Contents

Advertisement

Hard-drive carriers
Cooling shroud
3 Ensure that all cables are properly connected.
4 Close the system. See "Closing the System" on page 51.
5 Run the system board tests in the system diagnostics. See "Running the
System Diagnostics" on page 111.
If the tests fail, see "Getting Help" on page 119.

Troubleshooting the System Battery

NOTE:
If the system is turned off for long periods of time (for weeks or months), the
NVRAM may lose its system configuration information. This situation is caused by a
defective battery.
1 Re-enter the time and date through the System Setup program. See "Using
the System Setup Program and Boot Manager" on page 25.
2 Turn off the system and disconnect it from the electrical outlet for at least
one hour.
3 Reconnect the system to the electrical outlet and turn on the system.
4 Enter the System Setup program.
If the date and time are not correct in the System Setup program, replace
the battery. See "Replacing the System Battery" on page 89.
If the problem is not resolved by replacing the battery, see "Getting Help"
on page 119.
NOTE:
Some software may cause the system time to speed up or slow down. If the
system seems to operate normally except for the time kept in the System Setup
program, the problem may be caused by software rather than by a defective
battery.
102
Troubleshooting Your System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r210 ii systems e10sPoweredge r210 ii

Table of Contents