Troubleshooting System Memory - Dell External OEMR R210II Owner's Manual

Ultra-compact rack server
Hide thumbs Also See for External OEMR R210II:
Table of Contents

Advertisement

1 Locate the faulty fan indicated by the diagnostic software.
2 Turn off the system and all attached peripherals.
3 Open the system. See "Opening the System" on page 50.
4 Reseat the fan's power cable.
5 Restart the system.
If the fan functions properly, close the system. See "Closing the System" on
page 51.
6 If the fan does not function, turn off the system and install a new fan.
See "Cooling Fans" on page 74.
7 Restart the system.
If the problem is resolved, close the system. See "Closing the System" on
page 51.
If the replacement fan does not operate, see "Getting Help" on page 119.

Troubleshooting System Memory

CAUTION:
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
NOTE:
Invalid memory configurations can cause your system to halt at startup
without video output. See General Memory Module Installation Guidelines and
verify that your memory configuration complies with all applicable guidelines.
1 If the system is operational, run the appropriate online diagnostic test.
See "Running the System Diagnostics" on page 111.
If diagnostics indicates a fault, follow the corrective actions provided by
the diagnostic program.
2 If the system is not operational, turn off the system and attached
peripherals, and unplug the system from the power source. Wait at least 10
seconds and then reconnect the system to power.
3 Turn on the system and attached peripherals and note the messages on the
screen.