Diagnostic Error Codes - IBM HC10 - BladeCenter - 7996 Service Manual

Problem determination and service guide
Hide thumbs Also See for HC10 - BladeCenter - 7996:
Table of Contents

Advertisement

Diagnostic error codes

The following table describes the error codes that the diagnostic programs might
generate and suggested actions to correct the detected problems.
If the diagnostic programs generate error codes that are not listed in the table,
make sure that the latest level of the BIOS code is installed.
In the error codes, x can be any numeral or letter. However, if the three-digit
number in the central position of the code is 000, 195, or 197, do not replace a
CRU or FRU. These numbers appearing in the central position of the code have the
following meanings:
000
195
197
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7996," on page 11 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
001-292-000
Core system: failed/CMOS checksum failed. Load the BIOS default settings by using the
001-xxx-000
Failed core tests.
001-xxx-001
Failed core tests.
005-xxx-000
Failed video test.
030-xxx-000
Failed internal SATA interface test.
089-xxx-00n
Failed microprocessor test.
The blade workstation passed the test. Do not replace a CRU or FRU.
The Esc key was pressed to end the test. Do not replace a CRU or FRU.
This is a warning error, but it does not indicate a hardware failure; do not
replace a CRU or FRU. Take the action that is indicated in the Action
column, but do not replace a CRU or a FRU. See the description for
Warning in the section "Diagnostic text messages" on page 70 for more
information.
Action
Configuration/Setup Utility program and run the test
again (see the Installation and User's Guide for your
blade workstation).
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. (Trained service technician only)
Microprocessor.
b. (Trained service technician only) System
board assembly
71