POST error codes

The following table describes the POST error codes and suggested actions to
correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7996," on page 11 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
062
Three consecutive startup failures
101
Timer tick interrupt failure
102
Timer 2 test failure
151
Real time clock failure
Action
1. Run the Configuration/Setup Utility program,
select Load Default Settings, make sure that the
date and time are correct, and save the settings.
2. Reseat the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. Battery
b. (Trained service technician only)
Microprocessor 1
3. Replace the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. Battery
b. (Trained service technician only)
Microprocessor 1
c. (Trained service technician only) System
board assembly
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
1. Reseat the battery.
2. Clear CMOS. See "System board jumpers and
buttons" on page 7 for information about how to
clear CMOS.
3. Replace the following components one at a time,
in the order shown, restarting the blade
workstation each time:
a. Battery
b. (Trained service technician only) System
board assembly