Plumbing; Fittings; Electrical - Hayward Super Pump Owner's Manual

Super pump series
Table of Contents

Advertisement

Super Pump
Series __________
Pump Mounting (cont'd)

Plumbing

Use Teflon tape to seal threaded connections on molded plastic components. All plastic fittings must be new or thoroughly
cleaned before use. NOTE - Do NOT use Plumber's Pipe Dope as it may cause cracking of the plastic components.
When applying Teflon tape to plastic threads, wrap the entire threaded portion of the male fitting with one to two layers of
tape. Wind the tape clockwise as you face the open end of the fitting, beginning at the end of the fitting. The pump suction
and outlet ports have molded-in thread stops. Do NOT attempt to force hose connector fitting past this stop. It is only
necessary to tighten fittings enough to prevent leakage. Tighten fitting by hand and then use a tool to engage fitting an
additional 1 ½ turns. Use care when using Teflon tape as friction is reduced considerably; do NOT over-tighten fitting or
you may cause damage. If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to two additional
layers of Teflon tape, and re-install connector.

Fittings

Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets). Avoid fittings
that could cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and
Mechanical Officials (IAPMO) standards. Use a non-entrapping suction fitting in pool (multiple drains) or double suction
(skimmer and main drain).

Electrical

working on electrical connections.
WARNING –
won't reset, consult electrician to inspect and repair electrical system.
WARNING –
Insure that the electrical supply available agrees with the motor's voltage, phase, and cycle, and that the wire size is adequate
for the H.P. (KW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a
licensed electrician, and MUST conform to local codes and NEC regulations. Use copper conductors only.
WWW.HAYWARDPOOL.COM
_____
WARNING –
Hazardous Pressure. Pumps, filters, and other equipment/ components of a
swimming pool filtration system operate under pressure. Incorrectly installed and/or improperly tested
filtration equipment and/or components may fail resulting in injury and/or property damage.
WARNING –
All wiring must be done by a licensed electrician and must conform to all
local and national codes and regulations.
WARNING –
Ground and bond motor before connecting to electrical power supply. Failure
to ground and bond pump motor can cause serious or fatal electrical shock hazard.
WARNING –
Do NOT ground to a gas supply line.
WARNING –
To avoid dangerous or fatal electrical shock, turn OFF power to motor before
Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. If GFCI trips and
Fire Hazard. Match supply voltage to motor nameplate voltage.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS