Super Pump
Series__________

Product Specifications

Installation Instructions

WARNING –
This product should be installed and serviced only by a qualified professional.
Pump Location
from the weather. Select a well-drained area, one that will not flood when it rains. Do NOT install pump in a damp or
non-ventilated location. Keep motor clean. Pump motors require free circulation of air for cooling.
Pump Mounting
Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad with screws or
bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be solid, level, rigid, and vibration free.
Pump mount must:
Allow pump inlet height to be as close to water level as possible.
Allow use of short, direct suction pipe (to reduce friction losses).
Allow for gate valves in suction and discharge piping.
Be protected from excess moisture and flooding.
Allow adequate access for servicing pump and piping.

Pipe Sizing Chart

MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE
Pipe Size
Flow rate
[mm]
GPM [Liter/Min]
1 ½"
[50]
2"
[63]
IMPORTANT NOTES – No system should allow any higher than 8-ft/sec [2.44 meters/sec] water velocity. It is recommended
that a minimum length of piping, equivalent to 10 pipe diameters, be used between the pump suction inlet and any plumbing
fittings.
WWW.HAYWARDPOOL.COM
_____
Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction
loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight
(but not over-tightened). Suction line diameter must equal or be larger than the discharge line diameter.
Though the pump is designed for outdoor use, it is strongly advised to protect the electrical components
Water Velocity
ft/sec [meters/sec]
50.76
8
[192]
[2.44]
83.65
8
[317]
[2.44]
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
______________________________Page 5 of 15
Pipe Size
Flow rate
[mm]
GPM [Liter/Min]
2 ½"
119.40
[75]
[452]
3"
184.32
[90]
[698]
DIMENSION "A" TABLE
PUMP PART
DIMENSION
NUMBER
A
SP2600X5
13 3/8"
SP2605X7
14"
SP2607X10
14 3/8"
SP2610X15
15 1/2"
SP2615X20
16 1/2"
SP2621X25
16 1/2"
SP2607X102S
17"
SP2610X152S
17 1/2"
SP2615X202S
18 1/2"
Water Velocity
ft/sec [meters/sec]
8
[2.44]
8
[2.44]

Hide quick links: