Download Print this page
Hayward Super Pump Series Owner's Manual

Hayward Super Pump Series Owner's Manual

Hide thumbs Also See for Super Pump Series:

Advertisement

Super Pump
Super Pump
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed, including the following: Failure to follow instructions
can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the potential for personal injury.
WARNING
warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION
warns about hazards that will or can cause minor or moderate personal injury and/or
property damage and if ignored presents a potential hazard. It can also make consumers aware of
actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
Owner's Manual
Contents
Product Specific Warnings.........2
Introduction.................................4
Installation...................................7
Shaft Seal Replacement.............8
Replacement Parts.....................10
Troubleshooting.........................11
Warranty.......................................13
Registration ................................15
Hayward Pool Products
400 Connell Drive, Suite 6100, Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
700 Series
®
Series
®
IS26001 Rev-B
1

Advertisement

loading

Summary of Contents for Hayward Super Pump Series

  • Page 1: Table Of Contents

    The NOTICE label indicates special instructions that are important but not related to hazards. Hayward Pool Products 400 Connell Drive, Suite 6100, Berkeley Heights, NJ 07922 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2 Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 3 Unawareness of impending danger. Failure to perceive heat. Failure to recognize the need to leave the spa. Physical inability to exit the spa. Fetal damage in pregnant women. Unconsciousness resulting in danger of drowning. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 4: Introduction

    SAVE THESE INSTRUCTIONS General Information Introduction This manual contains information for the proper installation and operation of the Hayward Super Pump 700 Series. ® The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void warranty.
  • Page 5 1 ½ turns. Use care when using PTFE tape as friction is reduced considerably; do NOT over-tighten fitting or you may cause damage. If leaks occur, remove connector, clean off old PTFE tape, re-wrap with one to two additional layers of PTFE tape, and re-install connector. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 6 Pump MUST be permanently connected to circuit. Connect pump to an appropriately sized/rated branch circuit protector in accordance with local codes, regulations, and the National Electric Code (NEC). Use the circuit breaker as the master On-Off switch. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 7 If pump does NOT prime within five minutes, stop motor and determine cause. Be sure all suction and discharge valves are open when pump is running. See Troubleshooting Guide. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 8 Keep motor clean. Insure air vents are free from obstruction to avoid damage. Do NOT use water to hose off motor.  Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See “Shaft Seal Change Instructions” in this manual. Storage/Winterization WARNING –...
  • Page 9: Installation

    15. Fasten assembly to pump/strainer housing using the four (4) 3/8”" x 2" housing cap screws. (Be sure housing gasket is in place, and replace if damaged). Tighten alternately and evenly. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 10: Replacement Parts

    CAPACITOR SET, 1 HP TEFC, DOE * SPX2600CAP3 * Item #21, Capacitor Set, SPX2600CAP3 is only for pump model SP2670007X10 built AFTER 7/19/21. For replacement capacitors for pump model SP2670007X10 built BEFORE 7/19/21, please contact technical services. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 11: Troubleshooting

    Solution: Contact qualified professional to check that the wiring gauge is heavy enough. NOTE Your Hayward pump motor is equipped with an “automatic thermal overload protector.” The motor will automatically shut off if power supply drops before heat damage can build up causing windings to burn out. The “thermal overload protector”...
  • Page 12 4. Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine. Solution: All seal leaks should be replaced at once. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 13 This page left blank intentionally. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 14: Warranty

    The express limited warranty above constitutes the entire warranty of Hayward Pool Products with respect to its’ pool products and is in lieu of all other warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose. In no event shall Hayward Pool products be responsible for any consequential, special or incidental damages of any nature.
  • Page 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 16 Super Pump is a trademark of Hayward Industries, Inc. 2021 Hayward Industries. All rights reserved. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...

This manual is also suitable for:

Sp2670007x10Sp2600x5Sp2605x7Sp2607x10Sp2607x102sW3sp2605x7 ... Show all