B.11
Cable Types
The signal cable types (or similar) in Table B.44 are those recommended
by TANDBERG Television in order to maintain product EMC compliance.
Table B.44: Suitable Signal Cable Types
Signal Type
RS-232/RS-422 Data Out
Alarm Relay
ASI/HDSDI Out 1 and 2
ASI/SMPTE 310 In
Frame Sync
Ethernet (100BaseT)
Audio 1 and 2
Video Out
B.12
Compliance
B.12.1 Safety
This equipment has been designed and tested to meet the requirements of
the following:
EN 60950
IEC 60950
In addition, the product has been designed to meet the following:
UL 60950
15
The version of the standards shown is that applicable at the time of manufacture.
Reference Guide: TT1260 Contribution Receiver
ST.RE.E10100.1
Connector
Cable
9-way D-type Male
Belden 8162 CM 2PR24 shielded E108998 (typical)
9-way D-type Male
Belden 8162 CM 2PR24 shielded E108998 (typical)
BNC
Canford Audio BBC 1/3 PSF (type 2 video cable)
BNC
Canford Audio BBC 1/3 PSF (type 2 video cable)
BNC
Canford Audio BBC 1/3 PSF (type 2 video cable)
RJ-45
CAT 5E Data Cable S-FTP
9-way D-type Male to XLR
Canford Audio Cable DST 110 Ω
15-way D-type Male
Five-way screened Haurtian computer cable EL164535 'D'
15
European
Safety of information technology
equipment.
International Safety of information technology
equipment.
USA
Safety of information technology
equipment.
Technical Specification
Page B-27