TANDBERG TT1260 Reference Manual page 124

Contribution receiver, tt1260/dirbas, tt1260/cibas[/48] and options, software version 4.0.0 (and later)
Hide thumbs Also See for TT1260:
Table of Contents

Advertisement

Technical Specification
Item
Rated frequency
Voltage selection
Rated current
Input connector
Fuse
Fuse type
Fuse current rating
Power consumption
B.10.2 DC Supply Input (-48 Vdc Version)
NOTES...
1.
Only models TT1260/CIBAS/48 and TT1260/DIRBAS/48 use a DC power supply.
2.
Ensure correct polarity is maintained.
3.
The unit must have a protective earth.
Table B.43: DC Power Supply Specification
Item
Rated voltage
Rated current
Input connector
Fuse
Fuse type
Fuse current rating
Power consumption
Page B-26
Specification
50/60 Hz
Wide-ranging
1.5 A (100-240
Vac range)
CEE 22/IEC 3-pin male receptacle
Fuse in live conductor in power input filter at rear of unit. Do not use reversible plugs
with this equipment.
Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
1.6 A 250 V T HBC
45 W typical (NO options fitted)
180 W maximum
Specification
For connection to –48 Vdc supplies only.
(PSU input tolerance –40 to –60 Vdc). Correct polarity must always be observed.
2 A
Terminal block
Fuse in –48 Vdc connector at rear of unit.
Bussmann S505
Littelfuse 215
5x20mm time delay (T) 1500A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
5 A 250 V T HBC
45 W typical (NO options fitted)
180 W maximum
Reference Guide: TT1260 Contribution Receiver
ST.RE.E10100.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tt1260 contribution receiverTt1260 dirbas

Table of Contents