2. Note that the MEM LED on the light path diagnostics panel is lit; one of the
3. Open the cover and locate the lit LED beside the defective DIMM.
4. Follow the instructions in "Installing memory modules" on page 9 to remove and

Light path diagnostics panel

The following illustration shows the LEDs on the Level 2 Light Path Diagnostics
panel, which is on the side of the operator information panel.
For more information about the Light Path Diagnostics feature, see the Hardware
Maintenance Manual and Troubleshooting Guide. The following table describes the
LEDs on the Light Path Diagnostics panel.
Notes:
1. The server requires replaceable voltage regulator modules (VRMs) with
2. The server supports a maximum of two power supplies.
DIMMs in the memory cassette is defective.
Note: The lit LEDs light the connector retaining clips; look for a lit retaining clip
to identify a failed DIMM.
replace the DIMM.
PS1
TEMP
VRM
PCI
PS2
FAN
CPU
MEM
Light Path
Diagnostics
panel LED
Description
PS1
Power supply number 1 failure
PS2
Power supply number 2 failure
TEMP
System over temperature condition
FAN
Hot-swap fan or power-supply fan failure
VRM
VRM failure
CPU
Microprocessor failure
PCI
PCI failure
MEM
Memory failure
DASD
Hard disk drive failure
NR
Nonredundant power mode
NMI
Nonmaskable interrupt
SP
Remote Supervisor Adapter II failure
EXP
Attached expansion I/O failure
LOG
See event log or Remote Supervisor Adapter II log for non-optimal
condition information
OVER SPEC
Power supplies being overdriven
REMIND button
Press to invoke remind mode
microprocessors 3 and 4.
DASD NMI
EXP
OVER SPEC
NR
SP
LOG
REMIND
Chapter 6. Solving problems
57