Updating The Remote Supervisor Adapter Ii And Integrated Service Processor; Viewing The Configuration - IBM 88625RX Installation Manual

User manual
Hide thumbs Also See for 88625RX:
Table of Contents

Advertisement

10. Exit from ServeRAID Manager and remove the CD from the CD-ROM drive.
11. Restart the server.

Viewing the configuration

You can use ServeRAID Manager to view information about RAID controllers and
the RAID subsystem (such as arrays, logical drives, hot-spare drives, and physical
drives). When you click an object in the ServeRAID Manager tree, information about
that object appears in the right pane. To display a list of available actions for an
object, click the object and click Actions.
Updating the Remote Supervisor Adapter II and integrated service
processor
See the User's Guide on the IBM xSeries Documentation CD for information and
instructions for updating the software and firmware on the Remote Supervisor
Adapter II and on the server integrated service processor.
5. Click the icon to add the drives to the array.
6. If you want to configure a hot-spare drive, complete the following steps:
a. Click the Spares tab.
b. Select the physical drive that you want to designate as the hot-spare drive,
and click the icon to add the drive.
7. Click Next. The "Configuration summary" window opens.
8. Review the information in the "Configuration summary" window. To change the
configuration, click Back.
9. Click Apply; then, click Yes when asked if you want to apply the new
configuration. The configuration is saved in the controller and in the physical
drives.
Chapter 4. Configuring the server
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

88622rx8862Xseries 3658861

Table of Contents