Table Of Error Codes - Brother BAS-300G Instruction Manual

Direct drive programmable electronic pattern sewer
Hide thumbs Also See for BAS-300G:
Table of Contents

Advertisement

11. TABLE OF ERROR CODES

11. TABLE OF ERROR CODES
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before
opening the cover of the control box. Touching areas where high voltages are present can result in severe injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window.
Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
E010
Stop switch was pressed. Press the RESET key to clear the error.
Stop switch was pressed. Press the RESET key to clear the error.
E011
Press the
key to move the feed mechanism so that you can continue sewing.
The stop switch was still being pressed, or there is a problem with the stop switch connection.
E015
Turn off the power, and then check that connector P13 on the main PCB is properly connected.
Problem with the stop switch connection.
E016
Turn off the power, and then check that connector P13 on the main PCB is properly connected.
Foot switch is depressed to the 2nd step.
Turn off the power and check the foot switch.
(If using a two-pedal foot switch, the power was turned on while the start switch was still depressed, or the start
switch was pressed without the work clamp being lowered.)
E025
If the power has been turned on while the start switch was still depressed, turn off the power and check the start
switch.
If the start switch was depressed without lowering the work clamp, depress the work clamp switch to lower the work
clamp.
Foot switch is depressed to the 1st step. (Work clamp switch if using a two-pedal foot switch)
E035
Turn off the power and check the foot switch.
A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly.
E036
Use a foot switch that matches specifications, or initialize the memory switch settings.
Machine head tilting was detected after the power was turned on.
E050
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main PCB is properly connected.
Machine head tilting was detected while the sewing machine was operating.
E051
Turn off the power, and then check that connector P9 on the main PCB is properly connected.
Machine head tilting was detected when the power was turned on.
E055
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main PCB is properly connected.
An operation panel key was still being pressed when the power was turned on, or key is faulty.
E065
Turn off the power and check the operation panel.
67
DANGER
Cause and remedy
BAS-300G, BAS-311G, BAS-326G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bas-311gBas-326g

Table of Contents