High Voltage (120/240V) Pool Equipment
All OnCommand relays are double pole (they make/break both "legs" of 240V circuits) and are rated at 3HP/25A
at 240V (1½HP/25A at 120V). Refer to the diagram below for typical relay wiring.
240 VAC
120 VAC
120 VAC
Load
Load
Load
Wiring relays for 240 VAC
Wiring relays for 120 VAC
Wiring GFCB for 120 VAC
Pool Equipment
Pool Equipment
Pool Equipment
WARNING: Do not use the OnCommand to control an automatic pool cover. Swim-
!
mers may become entrapped underneath the cover.