On-Board Barometer; Battery And Charger Pack - Fluke RPM4-AD Operation And Maintenance Manual

Reference pressure monitor, air data version
Table of Contents

Advertisement

RPM4-AD™ OPERATION AND MAINTENANCE MANUAL
RPM4-AD A350K/A160K (fixed wing)
1. Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero is
2. Combined linearity, hysteresis, repeatability. Add + 1 Pa (0.00015 psi) in gauge mode for the resolution and short term
3. Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted one year
4. % of reading applies to 30 to 100 % of Q-RPT span. Under 30 % of Q-RPT span, the value is a constant which is the % of
1.2.2.2
The on-board barometer is used only to measure changes in atmospheric
pressure to provide dynamic compensation of the Q-RPT's atmospheric pressure
offset when making gauge pressure measurements and when displaying altitude
while measuring airspeed.
1.2.3

BATTERY AND CHARGER PACK

Power Requirements
Operating Temperature Range
Storage Temperature Range
Approx. Run Time, Full Charge
© 2005-2007 DH Instruments, a Fluke Company
LO Q-RPT
(absolute, gauge)
Used for: altitude
2
Precision
± 0.005 % of reading or
2.4 Pa, whichever is
greater
Measurement
± 0.008% of reading or
3
3.8 Pa, whichever is
Uncertainty
greater
performed by the operator: against zero pressure when vented in gauge mode, by direct comparison of one Q-RPT to the
other at the line pressure in differential mode, by comparison with a barometric reference in absolute mode. Absolute
mode predicted one year stability without AutoZ is ± (0.005 % Q-RPT span + 0.005 % of reading).
stability of the on-board barometer.
stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO "Guide to the
Expression of Uncertainty in Measurement." Add + 1 Pa (0.00015 psi) when measuring airspeed and using the Lo Q-RPT
to display altitude.
reading value times 30 %.

ON-BOARD BAROMETER

100 to 240 VAC, 50/60 Hz, 15 W max consumption
0 to 50 °C
- 20 to 50 °C
Meets MIL-T-28800D
Vibration
2 kg (4.4 lb)
Weight
8 cm H x 22.5 cm W x 20 cm D (3.1 in. x 8.9 in. x 7.9 in.)
Dimensions
Battery Type
Nickel Metal-Hydride
Battery Voltage
12 VDC
Battery Capacity
Typical:
Min:
Full charge from empty, 14 to 16 hours approx.
Charge Time
8 to 12 hours
Page 4
HI Q-RPT
(absolute, gauge)
Used for: airspeed at
ground altitude only
± 0.005 % of reading or
5.25 Pa, whichever is
4
4
greater
± 0.008% of reading or
8.4 Pa, whichever is
4
4
greater
9000 mAh
8200 mAh
HI Q-RPT
(differential)
Used for: airspeed at
varying altitude
± 0.005 % of reading or
5.25 Pa, whichever is
4
greater
± 0.008% of reading or
6.6 Pa, whichever is greater

Advertisement

Table of Contents
loading

Table of Contents