Sign In
Upload
Manuals
Brands
FLUKE Manuals
Monitor
RPM4-AD
FLUKE RPM4-AD Manuals
Manuals and User Guides for FLUKE RPM4-AD. We have
1
FLUKE RPM4-AD manual available for free PDF download: Operation And Maintenance Manual
FLUKE RPM4-AD Operation And Maintenance Manual (152 pages)
Reference Pressure Monitor, Air Data Version
Brand:
FLUKE
| Category:
Monitor
| Size: 2.7 MB
Table of Contents
Table of Contents
3
Tables
7
A B O U T T H I S M a N U al
9
1 Introduction
11
I N T R O D U C T I on
11
Product Overview
11
Specifications
12
General Specifications
12
Pressure Measurement Specifications
12
Quartz Reference Pressure Transducers (Q-Rpt)
12
Table 1. Quartz Reference Pressure Transducer (Q-RPT) Module Designations and Ranges
13
On-Board Barometer
14
Battery and Charger Pack
14
2 Installation
15
Unpacking and Inspection
15
Removing from Packaging
15
Inspecting Contents
15
Table 2. RPM4-AD Packing List
15
Site Requirements
16
Setup
16
Preparing for Operation
16
Front and Rear Panels
16
Front Panel
16
Figure 1. Front Panel
16
Rear Panel
17
Power Connection
17
85 To 264 Vac, 50/60 Hz Vac Power
17
Battery Pack
17
Figure 2. Rear Panel
17
Remote [Ent] Connection (Footswitch or Other Switch)
18
Connecting to Measure Pressure (Ps and Pt Ports)
18
Table 3. Making Pressure Connections to RPM4-AD
18
The Vent and Atm Ports
19
Check/Set Security Level
19
Sds Full Time off
19
Power-Up and Verification
20
Switch Power on
20
Check Pressure Measurement Operation
20
Checking Absolute Mode Pressure Measurement
20
Checking Gauge Mode Pressure Measurement
20
Short Term Storage
21
3 O P E R a T I O
23
User Interface
23
Main Run Screen
23
Figure 3. MAIN RUN Screen Display Fields
24
Function / Data Keypad Layout and Protocol
25
Figure 4. Keypad Layout
25
Remote [Ent] (Enter) Footswitch
26
Sounds
26
General Operating Principles
26
Q-Rpts and Q-Rpt Selection
26
Table 4. Position Designators of Q-Rpts in an RPM4-AD System
26
Gauge and Negative Gauge Measurement, Dynamic Compensation for Atmospheric Pressure
27
Table 5. Settings and What They Are Specific to (Range, Measurement Mode, Q-RPT, System)
27
Altitude and Airspeed Measurement
28
Rpm4-Ad A160K/A160K (Rotary Wing)
28
Rpm4-Ad A350K/A160K (Fixed Wing)
29
Pressure Ready/Not Ready
30
Parallel Measurement Mode
30
Differential Measurement Mode
31
Autozero Function
31
Sds Self Defense System
31
Use of the 12Vdc Battery/Charger Pack
32
Using Rpm4-Ad with a Ppc3 Controller/Calibrator
33
Direct Function Keys Summary
33
Figure 5. Battery Pack/Charger
33
Direct Function Keys
34
Range]
34
Table 6. Summary of RPM4-AD Function Key Operation
34
Rpm4-Ad A160K/A160K (Rotary Wing)
35
Rpm4-Ad A350K/A160K (Fixed Wing)
36
Unit]
37
Table 7. Available Unit of Measure Types by Active Q-RPT and Measurement Mode
38
Table 8. Available Unit of Measure Types by Active Q-RPT and Measurement Mode
38
Table 9. Default [UNIT] Choices by Active Q-RPT and Measurement Mode
39
Table 10. Default [UNIT] Choices by Active Q-RPT and Measurement Mode
39
Mode]
40
Differential Measurement Mode Operation
41
Autorange]
43
Leak Ck]/Rate of Change Measurement
43
Display]
44
Avg (Average)
46
Rate
47
Dev (Deviation)
48
Rpt
49
Hi/Lo
50
Freeze
51
Clean
52
Head]
52
Sds] (Self Defense System)
53
Sds in Differential Measurement Mode
55
Sds in Parallel Measurement Mode, Rpm4-Ad A160K/A160K Only
56
Autoz]
57
Autoz] in Gauge and Negative Gauge Mode
57
Autoz] in Absolute Mode
58
Autoz in Differential Mode
61
Ent]
62
Setup]
63
1Range
63
2Res> (Resolution)
63
3Stab
64
4Ul> (Upper Limit)
65
Over Pressure Function
66
5Atest
66
Special]
66
1Autoz
67
Table 11. Autoz on and off
69
Edit Autoz
71
2Remote
71
1Com1, 2Com2
72
3Ieee-488
72
4Format
72
5Rs232 Self-Test
73
3Head
73
4Sds
74
1Temp Open/Close
74
2Full Time On/Off
75
5Prefs
75
1Scrsvr
76
2Sound
76
3Time
77
4Id
77
5Level> (Security)
78
Table 12. Security Levels
79
6Punit
80
Table 13. Available Unit of Measure Types by Active Q-RPT and Measurement Mode
81
Table 14. UNIT Function - Available Units of Measure
82
Table 15. Available Unit of Measure Types by Active Q-RPT and Measurement Mode
83
7Internal
84
1Baro
84
2Readrt
85
Table 16. READRT - Display Update Rates
85
3Rpt2X
86
4Lo Vnt
86
5Log
86
8Cal
87
9Reset
87
1Sets
88
Units
88
3Atest
88
Table 17. Reset - Sets
88
Cal
89
All
89
Table 18. Reset - Cal
89
Table 19. Reset - All
89
4 Remote Operation
91
Overview
91
Interfacing
91
Rs232 Interface
91
Com1
91
Table 20. COM1 Pin Designations and Connections
91
Ieee-488
92
Com2
92
Programming Formats
92
Table 21. COM2 DB-9F Pin Designations
92
Classic Program Message Format
93
Enhanced Program Message Format
93
Using Command Type Commands
93
Using Query Type Commands
94
Commands
95
Programming Messages
95
Table 22. Program Message List
95
Error Messagess
96
Table 23. Error #S and Descriptions
96
Program Message Description Overview
97
Program Message Descriptions
98
Remote Airdata Setup Procedures
117
Status Reporting System
118
Error Queue
118
Status Byte Register
119
Table 24. 8 Bit Status Byte Register
119
Figure 6. Status Register Schematic
119
Standard Event Register
120
Table 25. 8 Bit Standard Event Register
120
Ready Status Register
121
Table 26. 8 Bit Ready Status Register
121
Ieee Std. 488.2 Common and Status Program Messages
122
Program Message Descriptions
122
Table 27. IEEE-488.2 Common and Status Program Message List
122
5 Maintenance, Adjustments a N D C a L I B R a T I O
125
Overview
125
Calibration of Quartz Reference Pressure Transducers (Q-Rpt)
125
Principle
125
Pa and Pm Coefficients
126
As Received and as Left Data
126
Equipment Required
127
Set-Up and Preparation
127
Rpm4 A160K/A160K (Rotary Wing)
127
Rpm4 A350K/A160K (Fixed Wing)
128
Recommended Calibration Point Sequence
128
A160K Q-Rpt Calibration Sequence
128
A350K Q-Rpt Calibration Sequence
129
Table 28. Calibration Point Sequence, A160K Q-RPT
129
Table 29. Calibration Point Sequence, A350K Q-RPT
129
Turning off Absolute and Negative Gauge Measurement Modes
130
Q-Rpt Calibration Using Caltool for Rpts Software
130
Editing and Viewing Q-Rpt Calibration Information
130
Q-Rpt Calibration/Adjustment Without Caltool for Rpts Software
131
Adjustment of On-Board Barometer
133
Reloading Embedded Software into Flash Memory
133
Subassembly Description and Location
134
Mini Micro Board
134
Power Supply Module
134
Figure 7. Internal View
134
Driver Board
135
On-Board Barometer
135
Q-Rpt Module
135
Hi Q-Rpt Module
135
Lo Q-Rpt Module
135
Display
135
Q-Rpt Module Pneumatic Schematic and Valve States
136
Rpm4-Ad A160K/A160K (Rotary Wing)
136
Table 30. Q-RPT Module Valve States, RPM4-AD A160K/A160K
136
Figure 8. Pneumatic Schematic and Valve States, RPM4-AD A160K/A160K (Rotary Wing)
136
Rpm4-Ad A350K/A160K (Fixed Wing)
137
Table 31. Q-RPT Module Valve States, RPM4-AD A350K/A160K
137
Figure 9. Pneumatic Schematic and Valve States, RPM4-AD A350K/A160K (Fixed Wing)
137
6 T R O U B L E S H O O T I N
139
7 A P P E N D I
139
Table 32. Troubleshooting Guide
139
7. Appendix
143
Figure 10. Remote [ENT] Connector Schematic
143
Remote [Ent]
143
Unit Conversion
144
Pressure
144
Altitude
144
Table 33. Pressure Unit of Measure Conversion Coefficients
144
Airspeed
145
8 Warranty
149
Overview
149
Table 34. DHI Authorized Service Providers
150
Advertisement
Advertisement
Related Products
Fluke RF303 Operators
Fluke RUSKA 7050
Fluke RSE300
Fluke RSE600
Fluke RUSKA 2482
Fluke COMARK RF500AP
Fluke COMARK RF500A/UK
Fluke CalPower RUSKA 3990 Series
Fluke CalPower RUSKA 3990-803
Fluke RF613
FLUKE Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More FLUKE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL