Summary of Contents for Kontron 2.5"-SBC-AML Series
Page 1
USER GUIDE 2.5"-SBC-AML/ADN Doc. User Guide, Rev. 1.1 Doc. ID: [To be Determined] www.kontron.com...
Page 2
2.5"-SBC-AML/ADN - User Guide, Rev. 1.1 This page has been intentionally left blank www.kontron.com // 2...
Page 3
In cases of doubt, please contact Kontron. This user guide is protected by copyright. All rights are reserved by Kontron. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the express written permission of Kontron.
ENVIRONMENTAL DAMAGE (COLLECTIVELY, "HIGH RISK APPLICATIONS"). You understand and agree that your use of Kontron devices as a component in High Risk Applications is entirely at your risk. To minimize the risks associated with your products and applications, you should provide adequate design and operating safeguards.
If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the revised user guide on our website.
Eye protection per manufacturer notice shall review before servicing. This symbol indicates general information about the product and the user guide. This symbol also indicates detail information about the specific product configuration. This symbol precedes helpful hints and tips for daily use. www.kontron.com // 6...
Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are requested to conform with the following guidelines.
General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the product, that are not explicitly approved by Kontron and described in this user guide or received from Kontron Support as a special handling instruction, will void your warranty.
8.2.5. Boot Setup Menu ...................................... 110 8.2.6. Save & Exit Setup Menu ..................................111 Appendix A: List of Acronyms ................................112 About Kontron ........................................113 List of Tables Table 1: Component Main Data ..................................17 Table 2: Environmental Conditions ................................. 18 Table 3: Standards and Certifications ................................
2.5"-SBC-AML/ADN - User Guide, Rev. 1.1 1/ Introduction This user guide describes the 2.5"-SBC-AML/ADN board made by Kontron. This board will also be denoted 2.5"-SBC- AML/ADN within this user guide. Use of this user guide implies a basic knowledge of PC-AT hardware and software. This user guide focuses on describing the 2.5"-SBC-AML/ADN board's special features and is not intended to be a standard PC-AT textbook.
Handle the board only by the edges To get the board running follow these steps. If the board shipped from KONTRON already has components like CPU cooler mounted, then skip the relevant steps below. 1. Turn off the PSU (Power Supply Unit) Turn off PSU (Power Supply Unit) completely (no mains power connected to the PSU) or leave the Power Connectors unconnected while configuring the board.
Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt fabrikantens instruktion VAROITUS! Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan lalteval- mistajan suosittelemaan tyyppiln Hävitä käytetty paristo valmistajan ohjeiden mukaisesti www.kontron.com // 15...
1x4-pin pitch 3.0 mm Wafer Firm w a re BIOS AMI uEFI BIOS w/ 256 Mb SPI Flash Watchdog Programmable WDT to generate system reset event H/W Monitor Voltages Temperatures Real Time Clock Processor integrated RTC www.kontron.com // 17...
BS EN 55032: 2015 + A1: 2020 CISPR 32: 2015 + A1: 2019 EN 61000-3-2: 2014 EN IEC 61000-3-2: 2019 + A1: 2021 EN 61000-3-3: 2013 + A2: 2021 BS EN 61000-3-2:2014 www.kontron.com // 18...
Page 19
EN IEC 61000-6-4: 2019 FCC Class B FCC CFR Title 47 Part 15 Subpart B, Class B ICES Class B ICES-003 Issue 7: 2020 Class B ANSI C63.4: 2014 ANSI C63.4a: 2017 UR (UL Recognized) www.kontron.com // 19...
The 2.5"-SBC-AML/ADN is designed to support Intel® Atom® x7000RE Series, Intel® Atom® x7000E Series, Intel® Core™ i3 N-Series and Intel® N-Series Processors. The BGA CPU is remounted from factory. Kontron has defined the CPU SKUs as listed in the following table for either standard or project-based board versions, so far all based on Embedded CPUs.
The power consumption is measured under the following software and hardware test condition. 2.5"-SBC-AML/ADN with Intel® Core™ i3-N305 (Octa Core @ 3.8 GHz) and Intel® Atom® x7835RE processor (Octa Core @ 3.6 GHz) Memory: 2x 8 GByte Micron LPDDR5 4800 SDRAM www.kontron.com // 21...
4.56 W 1.68 W Shutdown (S4 / S5) +19 V 11.57 W 1.55 W +9 V 4.3 W 1.61 W Power Saving (ErP / EuP) +19 V 2.2 W 224 mW +9 V 333 mW 159 mW www.kontron.com // 22...
2.5 GbE LAN1 & LAN2 RJ45 Connector CN10 USB 3.2 Gen 2 Port 1, 2 Type A Connector CN11 DP Port 1 Connector CN12 DP over USB 3.2 Gen 2 / Gen 1 Type C Connector Power Button LED1 Power LED www.kontron.com // 26...
Type and number of item described See Chapter Number of the chapter within this user guide containing a detailed description The abbreviation TBD is used for specifications that are not available yet or which are not sufficiently specified by the component vendors. www.kontron.com // 27...
MDI crossover mode, this pair acts as the BI_DD+/- pair. BI_D4+ / BI_D4- In MDI mode, this is the fourth pair in 2.5GBase-T and 1000Base-T, i.e. the BI_DD+/- pair.In MDI crossover mode, this pair acts as the BI_DC+/- pair. 'MDI' - - media dependent Interface www.kontron.com // 28...
Connected to ground, either directly or through a pulldown device Config2 Connected to ground, either directly or through a pulldown device AUX_CHp DisplayPort Auxiliary channel differential pair (+) Ground AUX_CHn DisplayPort Auxiliary channel differential pair (-) Hot_Plug DisplayPort hot plug detect Ground DP_PWR Power for connector www.kontron.com // 29...
USB 3.2 Rx differential pair (-) / DP Lane 3 Tx differential pair (-) CON_RX1P_C USB 3.2 Rx differential pair (+) / DP Lane 3 Tx differential pair (+) Ground * The power source of VBUX can be selected through JP4. www.kontron.com // 30...
White: D- Green: D+ Metallized Polyester Outer Shield ≥ 65% Interwoven 28 AWG Tinned Copper Drain Wire Tinned Copper Braid For USB 3.2 cabling it is required to use only HiSpeed USB cable, specified in USB 3.2 standard: www.kontron.com // 31...
The external I/O connector panel supports one power LED indicator (LED1) for power status indication. Table 17: LED Indicator LED1 Power LED (LED1) Status Description Green LED On S0 (Full On) Green LED Blink S3 (Suspend-To-RAM) LED Off S4 (Suspend-To-Disk), S5 (Soft Off) or EUP Mode or G3 (Mechanical Off) www.kontron.com // 32...
USB 2.0 differential pair (+) for channel B Ground Ground Ground Connector Type B2W, 2x5-pin, 2.0 mm pitch Mating Connector Vendor Dupont Housing Model No. WL2004H-2*5P(DP2.0) Terminal Model No. KB931-21T1A * The power source of +USBVCC can be selected through JP4. www.kontron.com // 35...
System Power LED (+). The LED lights up when users turn on the system power, and blinks when the system is in sleep mode. PWR_LED - System Power LED (-) Connector Type B2W, 2x4-pin, 2.0 mm pitch Mating Connector Vendor Pinrex Housing Model No. 720-75-204B03 Terminal Model No. 720-70-G00013 www.kontron.com // 36...
(-12 V) on hardware reset when the transmitter is empty or when loop mode operation is initiated. Received Data, receives data from the communications link. Data Terminal Ready, indicates to the modem etc. that the on-board UART is ready to www.kontron.com // 37...
Page 38
Data Carrier Detect, indicates that the modem or data set has detected the data carrier. TX+/- Transmitted Data differential pair sends data to the communications link. RX+/- Received Data differential pair receives data from the communications link. Power Supply GND signal www.kontron.com // 38...
+3.3 V / +5 V panel power supply) 500 mA max. +VPNL_EDP* +3.3 V / +5 V panel power supply 500 mA max. +VPNL_EDP* +3.3 V / +5 V panel power supply 500 mA max. No connection Ground www.kontron.com // 39...
Page 40
+12 V backlight power supply 500 mA max. +12V_S0 +12 V backlight power supply 500 mA max. No connection Connector Type B2W, 1x40-pin, 0.5 mm pitch Mating Connector Vendor I-PEX Model No. 20455-040E-12 * Panel Power can be selected through JP5. www.kontron.com // 40...
SPI slave chip select bit 1 CS0# SPI slave chip select bit 0 HOLD# SPI HOLD SPI slave serial data output SPI clock input Write-protect pin SPI slave serial data input Enable pin Connector Type B2B, 2x5-pin, 1.27 mm pitch www.kontron.com // 42...
3.3 V power supply Ground +3.3V 3.3 V power supply Ground PWROFF# M.2 module power enable USB_D+ USB 2.0 data differential pair (+) DISABLE# Wireless disable USB_D- USB 2.0 data differential pair (-) LED# Device active signal Ground www.kontron.com // 43...
Page 45
SIM card detect SUSCLK 32.768 kHz clock supply input +3.3V 3.3 V power supply Ground +3.3V 3.3 V power supply Ground +3.3V 3.3 V power supply * These pins are connected to CN13 SIM card wafer directly. www.kontron.com // 45...
Device active signal 2 LED2# Device active signal 2 WGR_D0P CNVio bus Rx Lane 0 (+) Ground Ground Ground Ground UART_WAKE# UART wake-up WGR_CLKN CNVio bus Rx clock (-) UART_RX UART data input BRI_RSP BRI bus Rx www.kontron.com // 46...
Page 47
W_DISABLE2# Wireless disable 2 W_DISABLE2# Wireless disable 2 PEWAKE0# PCIe wake W_DISABLE1# Wireless disable 1 W_DISABLE1# Wireless disable 1 Ground Ground WT_D1N CNVio bus Tx Lane 1 (-) WT_D1P CNVio bus Tx Lane 1 (+) Ground Ground www.kontron.com // 47...
Page 48
3.3 V standby power supply WT_CLKP CNVio bus Tx clock (+) +3.3V_SB 3.3 V standby power supply +3.3V_SB 3.3 V standby power supply Ground Ground * The board will auto-detect the module type and re-configure itself to an appropriate mode. www.kontron.com // 48...
Figure 21: SIM Card Wafer CN13 Table 29: Pin Assignment CN13 Signal Description Note +UIM_PWR Power +5 V or +3.3 V UIM_DATA Input or output for serial data UIM_CLK Clock signal UIM_RST Reset signal UIM_CD Card detect Ground www.kontron.com // 49...
The 2.0 mm pitch "eDP Panel Power Selection" jumper JP5 can be used to select eDP panel power voltage. Figure 27: eDP Panel Power Selection JP5 Table 34: Pin Assignment JP5 Jumper 1 Position Description Pin 1-2 Pin 2-3 +3.3 V +5 V “X’’ = Jumper set (short) and ‘‘-’’ = jumper not set (open) www.kontron.com // 52...
Figure 28: AT / ATX Power Mode Selection JP6 Table 35: Pin Assignment JP6 Jumper 1 Position Description Pin 1-2 Pin 2-3 ATX Power Mode (Default) AT Power Mode “X’’ = Jumper set (short) and ‘‘-’’ = jumper not set (open) www.kontron.com // 53...
8/ BIOS 8.1. Starting the uEFI BIOS The 2.5"-SBC-AML/ADN is provided with a Kontron-customized, pre-installed and configured version of AMI Aptio® V uEFI BIOS. AMI BIOS firmware is based on the Unified Extensible Firmware Interface (UEFI) specification and the Intel®...
Display information about the PCH ME Information Read only field. Display information about Intel Management Engine (ME) firmware System Language Read only field. [English] only Platform Information Sub-screen to board information. System Date Set System Date System Time Set System Time www.kontron.com // 55...
Save & Exit Product Information Product Name 2.5-SBC-ADN_AML BIOS Information BIOS Vendor American Megatrends Core Version 5.27 Compliancy UEFI 2.8; PI 1.7 Kontron BIOS Version ADNUPXT.113 (x64) Access Level Administrator FSP Information FSP Version 0C.02.89.40 RC Version 0C.E0.89.40 Build Date FSP Mode...
Page 57
Set the Date. Use Tab to switch between Data elements. Default Ranges: Year: 1998 - - 9999 Months: 1 - - 12 Days: Dependent on month Range of Years may vary. System Time [hh:mm:ss] Set the Time. Use Tab to switch between Time elements. www.kontron.com // 57...
Core Firmware Version 1.4.1 Release F1: General Help Board Firmware Version 1.0.0 Release F2: Previous Values SCM Info DB-8C-26-E2 F3: Optimized Defaults F4: Save & Exit Boot Counter ESC: Exit Version 2.22.1293 Copyright (C) 2025 AMI Read only sub-screen. www.kontron.com // 58...
SDIO Configuration eDP Configurations COM Configurations Intel® Ethernet Controller I226-IT - - C0:EA:C3:D2:0C:50 Intel® Ethernet Controller I226-IT - - C0:EA:C3:D2:0C:51 Setting items on this screen to incorrect values may cause the system to malfunction. www.kontron.com // 59...
Control Detection of the HD-Audio device. [Enabled] [Disabled] = HDA will be unconditionally disabled. [Enabled] = HDA will be unconditionally enabled. Power Mode [ATX mode] Read only item. Selection Restore AC Power [Power Off], Choose options for restoring AC power loss www.kontron.com // 60...
Page 61
2.5"-SBC-AML/ADN - User Guide, Rev. 1.1 Feature Option Description Loss [Last State] Power Saving Mode [Disabled], Enable / Disable power saving mode [Enabled] ME FW Image Re- [Disabled], Enable / Disable ME FW Image Re-Flash function. Flash [Enabled] www.kontron.com // 61...
Enable or Disable Endorsement Hierarchy Hierarchy [Enabled] Physical Presence [1.2], Select to Tell O.S. to support PPI Spec Version 1.2 or 1.3. Note Spec Version some HCK tests might not support 1.3. [1.3] TPM 2.0 Interface [TIS] Read only item Type www.kontron.com // 63...
Page 64
[TPM 1.2] will restrict support to TPM 1.2 devices [TPM 2.0], [TPM 2.0] will restrict support to TPM 2.0 devices [Auto] [Auto] will support both with default set to TPM 2.0 devices, if not found, TPM 1.2 devices will be enumerated www.kontron.com // 64...
State). This option may not be effective with some operating [Enabled] systems. ACPI Sleep State [Suspend Disabled], Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed. [S3 (Suspend to RAM)] www.kontron.com // 65...
Read only item through Create GSPI ACPI dev [Disabled], If set to ‘Kontron Linux BSP’ then a generic GSPI device will be used by Kontron Linux BSP. ‘Win10 RhProxy style’ supports this [Kontron Linux BSP], driver type under Win10. [Win10 RhProxy style]...
Output level [Low], Set the level of a DIO pin [High] Figure 37: BIOS Advanced Menu - - Miscellaneous - - Control KSC firmware Aptio Setup - - AMI Advanced Allows to control KSC firmware related settings. www.kontron.com // 67...
Locks write access to KSC OTP area during runtime. [Enabled] KSC OTP area limit [Disabled], Limit access to KSC OTP area during runtime. [Enabled] Figure 39: BIOS Advanced Menu - - Miscellaneous - - Update KSC firmware www.kontron.com // 68...
Description Generic LPC via eSPI [Disabled], Enable generic LPC via eSPI decode range. Decode 1 [Enabled] Base Address Value input Base address of the generic decode range. Valid between 0100h - - FFF0h. Must be 8-byte aligned. www.kontron.com // 69...
Select Action for this Watchdog stage [Reset], [Delay], [WDT Signal only] Assert WDT Signal [Disabled], Enable / disable assertion of WDT signal to baseboard on stage timeout. [Enabled] Stage 1/2/3 Timeout [1m], Select Timeout value for this Watchdog stage www.kontron.com // 70...
F1: General Help #4: 3V3_S0 : 3.4 V F2: Previous Values #5: 3V_BAT : 2.8 V F3: Optimized Defaults F4: Save & Exit Fan speed & control: ESC: Exit Version 2.22.1293 Copyright (C) 2025 AMI Read only sub-screen www.kontron.com // 72...
For example, enter 3 for 3 am and 15 for 3 pm. Wake up minute Value input Select 0 - - 59 for Minute Wake up second Value input Select 0 - - 59 for Second Wake up minute Value input 1 - 5 increase www.kontron.com // 73...
Select FunctionKey and KeyPad on Putty. [LINUX], [XTERMR6], [SCO], [ESCN], [VT400] Figure 46: BIOS Advanced Menu - - Serial Port Console Redirection - - Console Redirection EMS Settings Aptio Setup - - AMI Advanced Out-of-Band Mgmt Port [COM1] Terminal Type EMS [VT-UTF8] www.kontron.com // 75...
Page 76
[Hardware RTS/CTS], be sent to stop the data flow. Once the buffers are empty, a [Software Xon/Xoff] ‘start’ signal can be sent to re-start the flow. Hardware flow control uses two wires to send start / stop signals. www.kontron.com // 76...
Enables or Disables this Logical Device. [Enabled] Possible: [Use Automatic Allows the user to change the device resource settings. New Settings], settings will be reflected on this setup page after system restarts. [IO=3F8h; IRQ=4;], [IO=3F8h; IRQ=4;], [IO=2F8h; IRQ=3;] www.kontron.com // 77...
Enables or Disables this Logical Device. [Enabled] Possible: [Use Automatic Allows the user to change the device resource settings. New Settings], settings will be reflected on this setup page after system restarts. [IO=2F8h; IRQ=3;], [IO=2F8h; IRQ=3;], [IO=3F8h; IRQ=4;] www.kontron.com // 78...
[40 sec] Device power-up [Auto], Maximum time the device will take before it properly reports delay itself to the Host Controller. [Manual] ‘Auto’ uses default value: for a Root port it is 100 ms, for a Hub www.kontron.com // 79...
Page 80
2.5"-SBC-AML/ADN - User Guide, Rev. 1.1 Feature Option Description port the delay is taken from Hub descriptor. Device power-up Value input Dealy range is 1 .. 40 seconds, in one second increments. delay in seconds www.kontron.com // 80...
Use either + / - or numeric keys to set the value. Media detect count Value input Number of times the presence of media will be checked. Use either + / - or numeric keys to set the value. www.kontron.com // 81...
0IM20G [Auto], Mass storage device emulation type. (127.3GB) [Floppy], ‘Auto’ enumerates devices less than 530MB as floppies. [Forced FDD], ‘Forced FDD’ option can be used to force HDD formatted drive to boot as FDD. [Hard Disk] www.kontron.com // 83...
Set panel brightness value controlled by EC. Range is between 0 - - 100% Panel PWM [Normal PWM], Set panel PWM behavior [Inverted PWM] Panel PWM [200], Set panel PWM Frequency Frequency [1K], [5K], [10K], [20K], [30K], [40K] www.kontron.com // 84...
Internal Terminator switch control for RS-422 / RS- Terminator Switch 485 of COM1/2 [Terminator switch is enabled.] Control COM1/2 External [Terminator switch is disabled.], External Terminator switch control for RS-422 / Terminator Switch RS-485 of COM1/2 [Terminator switch is enabled.] Control www.kontron.com // 85...
[Enabled] → ←: Select Screen RC1p Support [Disabled] ↑ ↓: Select Item PAVP Enable [Enabled] Enter: Select Cdynmax Clamping Enable [Disabled] +/-: Change Opt. Cd Clock Frequency [Max CdClock freq F1: General Help based on Reference Clk] www.kontron.com // 88...
Page 89
[556.8 Mhz], [652.8 Mhz], [Max CdClock freq based on Reference Clk] Enable Display Audio [Disabled], [Enabled]: Display Audio Link will be enabled in Pre-OS. Link in Pre-OS [Enabled] [Disabled]: Display Audio Link will be disabled in Pre-OS. www.kontron.com // 89...
+/-: Change Opt. Dock Mode boot value [Undocked] F1: General Help Dock Mode upon S3 and S4 resume [No change] F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.22.1293 Copyright (C) 2025 AMI www.kontron.com // 91...
Page 92
Enable / Disable IUER Dock Functionality [Enabled] Dock Mode boot [Undocked], Choose Docked or Undocked as boot mode. value [Docked] Dock Mode upon S3 [No change], Keep it the same as Sx entry or toggle it. and S4 resume [Toggle] www.kontron.com // 92...
Lane configured as USB / SATA / UFS PCI Express Root Port 2 Lane configured as USB / SATA / UFS PCI Express Root Port 3 Lane configured as USB / SATA / UFS > PCI Express Root Port 4 www.kontron.com // 93...
PCIe EQ mode* [Use presets during EQ] EQ PH1 downstream port transmitter present* EQ PH1 upstream port transmitter present* Enable EQ phase 2 local transmitter override* [Disabled] Number of presents or coefficients used during phase 3* Preset 0* www.kontron.com // 94...
Page 95
PCIe EQ method [PCIe hardware EQ], Choose PCIe EQ method [PCIe fixed EQ] PCIe EQ mode [Use presets during Choose EQ mode. EQ], [Use coefficients Preset mode - - root port will use presets during EQ process, www.kontron.com // 95...
Port 1* [Enabled] Hot Plug* [Disabled] Configured as eSATA* Hot Plug supported External* [Disabled] Mechanical Presence Switch* [Disabled] Spin Up Device* [Disabled] SATA Device Type* [Hard Disk Drive] Topology* [Unknown] SATA Port 1 DevSlp* [Disabled] DITO Configuration* [Disabled] www.kontron.com // 100...
Page 101
Controls reporting if this port has an Mechanical Presence Switch Switch. [Enabled] Note: Requires hardware support. Spin Up Device [Disabled], If enabled for any of ports Staggerred Spin Up will be performed and only the drives which have this option enabled will spin up [Enabled] www.kontron.com // 101...
USB SW Device Mode Port #4* [Disabled] USB SW Device Mode Port #5* [Disabled] USB SW Device Mode Port #6* [Disabled] USB SW Device Mode Port #7* [Disabled] USB SW Device Mode Port #8* [Disabled] USB SW Device Mode Port #9* [Disabled] www.kontron.com // 102...
Page 103
Enable / Disable this USB Physical Connector (physical port). Connector #0..3 Once disabled, any USB devices plug into the connector will not [Enabled] be detected by BIOS or OS. USB HS Physical [Disabled], Enable / Disable this USB Physical Connector (physical port). www.kontron.com // 103...
Page 104
2.5"-SBC-AML/ADN - User Guide, Rev. 1.1 Feature Option Description Connector #0..9 [Enabled] Once disabled, any USB devices plug into the connector will not be detected by BIOS or OS. www.kontron.com // 104...
If only the user's password is set, then the password is a power on password and must be entered to boot or enter setup. Within the setup menu the user has administrator rights. Password length requirements are maximum 20 characters and minimum 3 characters. www.kontron.com // 105...
Restore Factory Keys [Yes], Force System to User Mode. [No] Install factory default Secure Boot key databases. Reset to Setup Mode [Yes], Delete all Secure Boot key databases from NVRAM. [No] www.kontron.com // 106...
It is highly recommended to keep a record of all passwords in a safe place. Forgotten passwords results in being locked out of the system. If the system cannot be booted because the User Password or the Supervisor Password are not known, contact Kontron Support for further assistance. HDD security passwords cannot be cleared using the above method. www.kontron.com...
[On]: The keys on the keypad will act as numeric keys. [Off]: The keys on the keypad will act as cursor keys. Quiet Boot [Disabled], Enables or disables Quiet Boot option [Enabled] Boot Option #1 [UEFI: Built-in EFI Shell], Sets the system boot order [Disabled] www.kontron.com // 110...
Restore / Load Default values for all the setup options. Save as User Defaults Save the changes done so far as User Defaults. Restore User Defaults Restore the User Defaults to all the setup options. UEFI: Built-in EFI Shell Save configuration and reset. www.kontron.com // 111...
2.5"-SBC-AML/ADN - - User Guide, Rev. 1.1 About Kontron Kontron is a global leader in IoT / Embedded Computing Technology (ECT) and offers individual solutions in the areas of Internet of Things (IoT) and Industry 4.0 through a combined portfolio of hardware, software and services.
Need help?
Do you have a question about the 2.5"-SBC-AML Series and is the answer not in the manual?