Repair Procedures - Scotsman C2648 - SERVICE MANUAL 11-2010 Service Manual

Hide thumbs Also See for C2648 - SERVICE MANUAL 11-2010:
Table of Contents

Advertisement

C2648 Service Manual

Repair Procedures

Purge valve
1
Push and hold the Off button to shut the
machine off.
2
Disconnect electrical power.
3
Remove front panel.
4
Unplug wires from valve coil.
Note: The coil can be removed from the valve body by rotating it 1/8 turn CW. After removal of the coil
the spring and plunger can be taken out.
5
Loosen screws holding valve bracket to mounting
bracket (circled area in photo).
6
Remove inlet and outlet hoses
7
Lift the valve and bracket up and off the keyhole
slots. Remove valve from cabinet.
8
Remove valve from bracket.
9
Reverse to reassemble
10 Push and release the On button to restart the
machine
Water level sensor
1
Push and hold the Off button until the machine shuts
off.
2
Remove the front panel.
3
Locate water level sensor.
4
Squeeze the locking tabs together and pull the sensor up and out of the sump.
5
Unplug the electrical connection from the sensor.
6
Reverse to reassemble.
November 2010
Page 44
Electrical Shock Hazard.
Disconnect electrical power
before beginning.

Advertisement

Table of Contents
loading

This manual is also suitable for:

C2648sr-3C2848mr-3

Table of Contents