Scotsman C1448 Installation And User Manual

Scotsman C1448 Installation And User Manual

Modular cuber prodigy plus d series
Hide thumbs Also See for C1448:

Advertisement

Installation and User's Manual for
Modular Cuber
Prodigy Plus D Series Models C1448, C1848

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman C1448

  • Page 1 Installation and User’s Manual for Modular Cuber Prodigy Plus D Series Models C1448, C1848...
  • Page 2: Table Of Contents

    C1448, C1848 D Air and Water Cooled User Manual Introduction The design of this modular cuber is the result of years This installation and user manual is divided into of experience and testing. Standard features include three main sections: Installation, which provides...
  • Page 3: Installation: Product Specifications

    C1448, C1848 D Air and Water Cooled User Manual Installation: Product Specifications Location Limitations: The product is designed to be Environmental Limitations installed indoors, in a controlled environment. Air Minimum Maximum cooled models discharge very warm air into the room Air temperature out the back.
  • Page 4: Product Information

    • A=Condenser type. A=air cooled. W=water cooled approved by Scotsman. • -32=Electrical code. -32=208-230 single phase. Scotsman reserves the right to make design changes -3=208-230 three phase and/or improvements at any time. Specifications and • D=Series revision code. D=4th series design are subject to change without notice.
  • Page 5: Product Description & Electrical Requirements

    C1448, C1848 D Air and Water Cooled User Manual Product Description & Electrical Requirements Dimensions Model Electrical Condenser Minimum Suggested Maximum w” x d” x h” Circuit Fuse Size Fuse Size* Ampacity 48 x 24 x 29 C1448SA-32 208-230/60/1 17.7...
  • Page 6: Cabinet Layout, Air And Water Cooled

    C1448, C1848 D Air and Water Cooled User Manual Cabinet Layout, Air and Water Cooled December 2014 Page 5...
  • Page 7: Water

    A triple head filter is recommended for the potable Cube ice machines use more water than what ends water. Either the Scotsman SSM3 taste and odor filter up in the bin as ice. While most water is used during system, or the ADS-AP3 Aqua Patrol system. RO ice making, a portion is designed to be drained out water.
  • Page 8: Panel Removal

    C1448, C1848 D Air and Water Cooled User Manual Panel Removal 1. Locate and loosen the two screws at the bottom edge of the front panel. 2. Pull the front panel out at the bottom. 3. Lower the front panel down and off the machine.
  • Page 9: Uncrate And Set Up

    C1448, C1848 D Air and Water Cooled User Manual Uncrate and Set Up Begin with unpacking the ice storage bin. Remove the carton, and using part of the carton as a cushion, tip Open door to access On the bin on its back to remove the skid and attach the and Off switch buttons.
  • Page 10: Plumbing Requirements

    Water cooled models have a 1/2" FPT drain fitting A triple head filter is recommended. Either the plus an additional 3/8” FPT condenser inlet water Scotsman SSM3 taste and odor filter system, or the connection. ADS-AP3 Aqua Patrol system. Field Supplied...
  • Page 11: Drains

    C1448, C1848 D Air and Water Cooled User Manual Drains All models require drain tubing to be attached to them. 3. Route the drain tubing to building drain. Follow Air cooled models have a single ¾” FPT drain fitting local codes for air gap.
  • Page 12: Electrical

    C1448, C1848 D Air and Water Cooled User Manual Electrical The machine is not supplied with a power cord, the machine should be hard-wired. The dataplate on the back of the cabinet details the power requirements, including voltage, phase, Ground Wire minimum circuit ampacity and maximum fuse size.
  • Page 13: Initial Start Up

    13. Fill out and mail warranty registration form or valves and harvest assist devices will activate then register on line at www.scotsman-ice.com. the compressor and water pump will start. If its an air cooled model the fan motors will begin to turn. The Typical Ice Making Cycle Times (minutes).
  • Page 14: Adjustments

    C1448, C1848 D Air and Water Cooled User Manual Adjustments Bridge Thickness - For Service Tech Only 1/8 - 3/16” bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove curtain. 4. Use a box wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness.
  • Page 15: Water Flush Setting

    C1448, C1848 D Air and Water Cooled User Manual Water flush setting The water flush is factory set to the automatic position, suitable for most water conditions. The setting can be changed to one of 5 manual settings or left on automatic.
  • Page 16: Use And Operation

    Contact an authorized into the cabinet and cause serious damage. Damage Scotsman service agent and have the machine caused by foreign material is not covered by warranty. cleaned, de-scaled and sanitized.
  • Page 17: Switches

    C1448, C1848 D Air and Water Cooled User Manual Switches The two switches – on and off - can be accessed from Use of control the front of the machine. Vari-Smart Control Area Status De-Scale 02-4294-01 Graphic Rev. B Full...
  • Page 18: Cleaning, Sanitation And Maintenance

    5. Observe code display, when it blinks the characters “A d 1” immediately go to the next step. 6. Pour 24 ounces of Scotsman Clear 1 ice machine Push Here scale remover into the reservoir. The unit will circulate the scale remover, then drain and flush it.
  • Page 19 Ice Storage Bin Remove and discard all ice. Mix a solution of Scotsman Clear 1 ice machine scale remover and wash all interior surfaces of the ice storage bin to remove any mineral scale build up. Pour excess cleaner solution into the bin’s drain.
  • Page 20: Air Cooled Condenser Filter

    C1448, C1848 D Air and Water Cooled User Manual Air cooled condenser filter 1 Pull air filters from their louvered mounts. Exterior Panels 2 Wash the dust and grease off the filter. The front and side panels are durable stainless steel.
  • Page 21: What To Do Before Calling For Service

    C1448, C1848 D Air and Water Cooled User Manual What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. • High discharge temperature.
  • Page 22 SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com 17-3495-02...

This manual is also suitable for:

C1848