C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Introduction The design of this modular remote cuber is the result The Installation section provides the trade person with of years of experience with remote ice machine the information needed to properly install and start refrigeration systems.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Installation: Product Specifications Location Limitations Warranty Information This ice system is made up of three parts, the ice The warranty statement for this product is provided making machine, or head; the remote condenser; and separately from this manual.
Scotsman. • 32=Electrical code. -32=208-230/60/1, -3= 208- 230/60/3 Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and • E=series revision code. E=5th series. design are subject to change without notice.
• Includes a headmaster valve for discharge pressure control. Headmaster kit available for certain MAC condensers, kit number is RCKCME6GX. Note: Do not use C1848R or C2148R with MAC • Fan motor on all the time or controlled to be on whenever the ice machine is operating.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Condenser and Machine Layouts .88 DIA. ELECTRICAL 29.50 in INLET 74.9 cm DISCHARGE LINE 1/2" MALE CPLG. 2.75 LIQUID LINE 3/8" MALE CPLG. 38.47 in 97.7 cm Cond. Fins 32.32 in 82.1 cm 35.72 in...
A triple head filter is recommended. Either the In addition, this product is designed to automatically Scotsman SSM3 taste and odor filter system, or the vary the amount of water purged based on the purity ADS-AP3 AquaPatrol system.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Panel Removal 1. Locate and loosen the two screws at the bottom edge of the front panel. 2. Pull the front panel out at the bottom until it clears the base.
Use the following for planning the placement of the Configurations that do NOT meet these requirements condenser relative to the ice machine must receive prior written authorization from Scotsman. Location Limits - condenser location must not exceed ANY of the following limits: Do NOT: •...
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual For The Installer: Remote Condenser Locate the condenser as near as possible to the Meet all applicable building codes. interior location of the ice machine. Roof Attachment Spacing. Some unique installations have a ceiling Install and attach the remote condenser to the roof over the top of the condenser fan.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Line Set Routing and Brazing Do not connect the refrigerant tubing until all insert them into valve stubs. routing and forming of the tubing is complete. Note: Be sure tube and stubs are round, dress with Final connections requires brazing, steps must swage tool if needed.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Plumbing Requirements Drains All models require connection to cold, potable water. A hand actuated valve within site of the machine All models require drain tubing to be attached to them. is required.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Electrical The machine is not supplied with a power cord, the 1. Remove the junction box cover and route the machine must be hard-wired. power cord through the access hole and properly attach the power supply wires to the leads in the The dataplate on the back of the cabinet details junction box.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Final Check List: 1. Is the unit located indoors in a controlled environment? Open door to access On and Off switch buttons. 2. Is the condenser located where it can receive adequate cooling air? 3.
F. water C1448R 14-15 Note: Moving the curtain during the Freeze cycle has no affect on unit operation. C1848R 9-10 C2148R 8. Observe the Ready for Harvest indicator light. It may blink early in the freeze cycle, that is normal.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Adjustments Bridge Thickness - For A Service Tech Only 1/8 - 3/16” bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove left curtain. 4.
If the Clean light is on, the machine has determined that it may need to be cleaned. Contact an authorized Scotsman service agent and have the machine cleaned, de-scaled and sanitized. February 2016 Page 16...
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Switches The two switches – on and off - can be accessed from the front of the machine. 02-4294-01 Graphic Rev. B To switch the machine OFF, push and release the Off Full Rotate knob to set ice level Yellow Arrow = Max Ice...
5. Observe code display, when it blinks the characters “A d 1” immediately go to the next step. 6. Pour 24 ounces of Scotsman Clear 1 ice machine Push Here scale remover into the reservoir. The unit will circulate the scale remover, then drain and flush it.
Page 20
Remove and discard all ice. Mix a solution of Rinse and return probes to holder. Scotsman Clear 1 ice machine scale remover and wash all interior surfaces of the ice storage bin to remove any mineral scale build up. Pour excess Holder cleaner solution into the bin’s drain.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual Remote condenser The condenser fins will need to be cleaned. Push and release the Off button. Wait until the machine stops. Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart.
C1448, C1848, C2148 E Series Remote Condenser Models - User Manual What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. •...
Page 23
SCOTSMAN ICE SYSTEMS 101 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com 17-3599-04 Rev. A Last Revised 07-02-18...
Need help?
Do you have a question about the C1848R and is the answer not in the manual?