C2648 D Remote Condenser Models - User Manual Introduction The design of this modular remote cuber is the result The Installation section provides the trade person with of years of experience with remote ice machine the information needed to properly install and start refrigeration systems.
C2648 D Remote Condenser Models - User Manual Installation: Product Specifications Location Limitations Power Supply This ice system is made up of three parts, the ice Minimum Maximum making machine, or head; the remote condenser; and 208-230 volt 198 volts 253 volts the interconnecting tubing.
Scotsman. listed there. Scotsman reserves the right to make design changes Options: and/or improvements at any time. Specifications and There are several options available for field design are subject to change without notice.
• Fan motor on all the time or controlled to be on whenever the ice machine is operating. • U.L. listed for the ice machine • Non-Scotsman condensers must have prior Scotsman Engineering approval for warranty coverage to be in effect.
Adjustments of purge due to local water conditions are not covered by warranty. A triple head filter is recommended. Either the Scotsman SSM3 taste and odor filter system, or the ADS-AP3 AquaPatrol system. Water flow is 2.5 GPM when filling the reservoir.
5. Lift up the front of the top panel, push it back an inch, then lift to remove. Scotsman BH1100, BH1300, BH1600: Position back of ice machine about 2 3/8” from back of bin. 6. Locate and remove the screws holding each side panel to the base.
Page 9
Remote Condenser Location Configurations that do NOT meet these requirements must receive prior written authorization from Use the following for planning the placement of the Scotsman. condenser relative to the ice machine Do NOT: Location Limits - condenser location must not exceed ANY of the following limits: •...
Page 10
C2648 D Remote Condenser Models - User Manual For The Installer: Remote Condenser Roof Attachment Locate the condenser as near as possible to the Install and attach the remote condenser to the roof interior location of the ice machine. of the building, using the methods and practices of construction that conform to the local building codes, Note: The location of the condenser is relative to the including having a roofing contractor secure the...
C2648 D Remote Condenser Models - User Manual Precharged Line Routing Do not connect the precharged tubing until all routing power supply to the condenser. and forming of the tubing is complete. See the Caution: Do NOT kink the refrigerant tubing while Coupling Instructions for final connections.
C2648 D Remote Condenser Models - User Manual Coupling Instructions The couplings on the ends of the pre-charged line It is important that ONLY the nut on the pre-charged sets are self-sealing when installed properly. tube be turned, or the diaphragms will be torn out by the piercing knives and they will be loose in the Follow these instructions carefully.
C2648 D Remote Condenser Models - User Manual Plumbing Requirements All models require connection to cold, potable water. 1. Connect water supply to water inlet fittings. A hand actuated valve within site of the machine is 2. Connect drain tubing to drain fitting. required.
C2648 D Remote Condenser Models - User Manual Electrical The machine is not supplied with a power cord, one Electrical connections are made inside the junction must either be field installed or the machine hard- box in the back panel of the ice machine. wired.
C2648 D Remote Condenser Models - User Manual Final Check List: 1. Is the unit located indoors in a controlled environment? 2. Is the unit located where it can receive adequate cooling air? 3. Has the correct electrical power been supplied to the machine? 4.
13. Fill out and mail the warranty registration form or positions. Warm air will be discharged from the go on line at Scotsman’s website, www.scotsman- condenser coil. ice.com and register it there.
C2648 D Remote Condenser Models - User Manual Adjustments Bridge Thickness - For A Service Tech Only 1/8 to 3/16” bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove left curtain. 4. Use a box wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness.
If the Clean light is on, the machine has determined that it may need to be cleaned. Contact an authorized Scotsman service agent and have the machine cleaned, de-scaled and sanitized. Other Indicators Removal of the front panel allows review of the Code Display and Component Indicator Lights.
C2648 D Remote Condenser Models - User Manual Switch Panel Area The On and Off switches are front accessible at the The ultrasonic ice level control allows control of the lower left corner. point that the ice machine stops making ice. Reasons for this include: Switch Door •...
C2648 D Remote Condenser Models - User Manual Options and Other Information Smart-Board When this option is present there is an additional display panel in the area below the main control board. It is not visible when the front panel is on. The Smart-Board’s features include: •...
5. Wait until the Code Display blinks the characters cabinet where the reservoir was resting. A d 1, then pour 24 ounces of Scotsman Clear 19. Thoroughly wash the interior of the evaporator 1 Scale remover into the water reservoir. The...
Page 22
27. Push and release the green ON button to resume ice making. Remove and discard all ice. Clean Storage Bin Mix a solution of Scotsman Clear 1 ice machine scale remover and wash all interior surfaces of the ice storage bin to remove any mineral scale build up.
C2648 D Remote Condenser Models - User Manual Remote condenser and other maintenance The condenser fins will need to be cleaned. Push and release the Off button. Wait until the machine stops. Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart.
C2648 D Remote Condenser Models - User Manual What to do before calling for service Reasons the machine might shut itself off: To Manually Reset the machine. • Lack of water. 1. Open the switch door • Freeze cycle takes too long. 2.
Page 25
SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com 17-3545-01...