PowerVault MD Storage

The controllers connect to the PowerVault MD iSCSI storage array, which is a
RAID subsystem.
RAID storage subsystems are designed to eliminate single points of failure.
Each active component in the storage subsystem is redundant and hot-
swappable. The solution supports typical RAID configurations including
RAID 1, RAID 5, RAID 6, RAID 10, and RAID 50.

BPS

The BPS provides continuous power to the controllers. Each controller
receives its power from a dedicated BPS and from the power grid. Each
controller regularly monitors the BPS battery status, which requires the BPS
to maintain a minimum level of power for normal operation.The BPS has
sufficient battery power to allow the controllers to execute it's shutdown
procedure.
The BPS enables the controllers to use the cache as NVRAM. The BPS
provides the clustered solution enough time to write all the data from the
cache to the disk if the controller experiences a loss of power.
NOTE:
You can view the BPS events on the NAS Manager.

Cache

Each controller is equipped with 12 GB of RAM, most of which is used for
caching.
The file system uses the cache efficiently to provide fast and reliable writes
and reads. Writing or modifying files occurs first in the cache. Data is then
mirrored to the peer controller's cache. This feature ensures that all
transactions are duplicated and secured.

iSCSI Connections

iSCSI connections provide the controllers access to the storage subsystem
(MD32x0i/MD36x0i) through Ethernet switches.