Dell PowerVault 50F Installation And Troubleshooting Manual page 65

Dell powervault 56f 16-port fibre channel switch installation and troubleshooting guide
Hide thumbs Also See for PowerVault 50F:
Table of Contents

Advertisement

support.dell.com
switch:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [0] 256
integer must be between 1 and 239 - please re-enter
Domain: (1..239) [0]
BB credit: (1..16) [16] one
Input not acceptable, please re-enter
BB credit: (1..16) [16]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000] 4900
integer must be a multiple of 1000 - please re-enter
E_D_TOV: (1000..5000) [2000] 5000
Data field size: (256..2112) [2112] ^D
Committing configuration...done.
A number of parameters control the overall behavior and operation of the fabric. Some
of these values, such as the domain, are normally assigned automatically by the fabric
and may be different from one switch to another in the fabric. However, other param-
eters, such as the buffer-to-buffer credit or the time out values, may be changed to
suit particular application programs or operating environments, but must be in agree-
ment among all switches to allow formation of the fabric.
Table 4-4 defines the settings affecting the fabric.
% 
Domain
BB Credit
R_A_TOV
E_D_TOV
Data Field Size
Non-SCSI Tachyon Mode
Disable Device Probing
VC Encoded Address
Mode
Disable Translative Mode
Per-frame Route Priority
$ 
 
Number
1
Number
16
Number
10000
Number
2000
Number
2112
Boolean
0
Boolean
0
Boolean
1
Boolean
Boolean
0
PowerVault 56F 16-Port Fibre Channel Switch Commands

Varies
1 - 16
E_D_TOV * 2 to
120000
1000 to R_A_TOV / 2
256 to 2112
0 or 1
0 or 1
0 or 1
0
0 or 1
0 or 1
4-9